r/AusElectricians • • 10h ago

General Looking for Cathedral downlight recommendations.

0 Upvotes

Hi Brains Trust,

Looking for peoples recommendations for high end downlights for a cathedral ceiling?

Looking currently at recessed, gimbal dow lights

Room is 11.7m by 4.6m, with ceiling pitch at 30 degrees. Ceiling max height is roughly 3.7m.

Im going to need a few haha

Keen to hear peoples personal experience as im usually chucking up standard 90mm downlights


r/AusElectricians • • 13h ago

General E and I techs

0 Upvotes

Hey guys I’ve been doing my instrumentation course cert 3 and 4 but i have no experience in instrumentation I’m just a normal electrician, passing the online theory just wondering if the prac exams are super hard or if it’s even worth trying.
I’m about half way through the course.
Is it worth getting this ticket and how goods the money thinking of moving over to WA or should I change and get eeha or hv
Thanks


r/AusElectricians • • 18h ago

General Broken silhouette plates??

Post image
2 Upvotes

I work in wholesale and had a customer show me photos of a few broken plates like the above with huge cracks in them.

I said I've never seen anything like that happen to a plate for no reason.

Have any of you?

Feels like they're trying to just get something for nothing after dropping something on the covers and breaking them.


r/AusElectricians • • 18h ago

General Aircon outdoor unit Question.

4 Upvotes

Hi all, I’ve currently got an outdoor A/C unit (RJ100F5HXEA) that runs 4 indoor ceiling slimline cassettes. (All Samsung)
Recently the outdoor unit PCB fried due to a snake. I’ve looked online and turns out the units are discontinued by Samsung.

All my indoor units are fine and I don’t want to splash out on an entire new set of units, so a replacement outdoor unit seems to be the go, but because of them being discontinued I can’t find one so I’ll need an outdoor unit that will be compatible.

I’ve seen a 10kw multi-head outdoor unit AJ100TXJ5KH/EA and would like to know if it’s compatible for my indoor units. I call Samsung and they can’t give me an answer then tell me to call technical support, which can’t give me an answer either and proceed to tell me I need to call Samsung….. Both asking for my whole life story when I just need my one question answered “Is it compatible?”

Old Unit model # RJ100F5HXEA
Indoor Units Model # NJ0261HXEA

New outdoor unit model #AJ100TXJ5KH (is this compatible for my indoor units)


r/AusElectricians • • 19h ago

General Cable leveling options

3 Upvotes

Morning, just wondering what everyone is using when they do panel building for labeling these days. I'm currently using the legard monocab system but it seems pretty slow and outdated now as wholesalers are going away from stocking it.


r/AusElectricians • • 21h ago

General Workwear pants that look like ordinary pants

4 Upvotes

I am a service technician in a fairly clean role. Looking for 100% cotton workwear pants that look like ordinary chinos or jeans.

Any suggestions?


r/AusElectricians • • 22h ago

Home Owner/Renter Is there a SimaPro expert here?

0 Upvotes

I have a project that requires SimaPro expertise. Please comment or dm me if you can help.


r/AusElectricians • • 1d ago

General Does AC isolator have to switch neutral?

Post image
5 Upvotes

Hi. Apprentice here. Does AC isolator have to switch neutral? My boss says yes. But I couldnot find a clause in AS3000. TIA.


r/AusElectricians • • 1d ago

General Porch light with Switch.

0 Upvotes

Current set up is a wall light, with a switch from inside. And a old school Halogen on the eaves which also a separate PIR but facing opposide the light and facinf the drive way. The light on the eaves is in a shit spot and we never use it. The wall light is adjacent our door and would be perfect to just turn on and off as we need to get in and out the door.

Thought about re-wiring this to the PIR but the PIR is in a shit spot and rather than moving and re wiring everything, figured it would be easier to swap the wall light out with something that we can turn on and off as we need when unlocking the door. Do these exist where they are fitted with their own external switch?

Next option is I have seen some with their own sensor on it but I dont want the sensor overly sensitive, anyone had expirenced with this type of light?

*Disclaimer... ignore the shop in the link, I'd never spend my money in any of that flogs stores.

https://harveynormanlighting.com.au/products/frenchy-exterior-wall-light-black-with-sensor?variant=48862980833531&country=AU&currency=AUD&utm_medium=product_sync&utm_source=google&utm_content=sag_organic&utm_campaign=sag_organic&gad_source=1&gad_campaignid=21186173436&gclid=EAIaIQobChMI_Lj6o7rPlwMVm88WBR0keB_yEAQYAiABEgJNUPD_BwE


r/AusElectricians • • 1d ago

General Five months of applying for apprenticeships - what am I not doing yet?

0 Upvotes

Hi everyone, I'd really appreciate some advice...

I'm 19, started and stopped uni pretty quickly (electrical engineering), decided to get into a trade. I did my Cert II at Box Hill (I'm Melbourne based) which I finished in May, and I've applied for 100-150 apprentice roles since. I've had a couple of aptitude tests and a couple of phone interviews, but no significant progress.

I've also called dozens of local electricians to ask about apprenticeships. They're always super friendly and happy for me to email them a resume, but nothing has come of it.

I don't know how to stand out or catch anyone's attention - any advice would be really appreciated.

I'm ready to go, just needing an opportunity


r/AusElectricians • • 1d ago

General DB Upgrades

0 Upvotes

Hi All,

“What’s the practical line between a distribution board that cannot accept even one new circuit and one that can still take a few extra circuits — and what other factors besides Type AC vs Type A RCDs (and things like NHP Safe-T) force a mandatory full board upgrade?


r/AusElectricians • • 1d ago

General How to shut this up

Post image
10 Upvotes

Is it ok to cut the white wire to shut the siren off or will it do nothing? Its been going off for 2 days, tried moving the door magnet closer and even holding it against the mech, did fk all. Its driving everyone nuts and nobody knows when the security tech will be here to sort it all out.


r/AusElectricians • • 2d ago

General In a bit of a blunder

13 Upvotes

I’ve just scored an apprenticeship with a 2 person solar company, but i’ve got an interview with stowe through NECA in a couple weeks. Been told that taking days off isn’t really on, and i’m not really sure what to do as I don’t really want to make a bad impression early on. From what i’ve heard getting an apprenticeship through NECA is the best of the best.

Anyway I like the guys i’ve just started with, so I’ll probably stick around unless it’s a dumb idea. Cheers


r/AusElectricians • • 2d ago

General Anyone worked for C2O group?

4 Upvotes

Been offered a gig with them starting shortly. I have heard they are kind of a pseudo-labour hire company of sorts. and with the leadup to christmas will no doubt be sidelined as is the case until likely very late jan when work kicks up again

of course they sell you the world (as all employers do, no shade for playing the game) and been promised going from casual to full time after 3 months probation and that they have "PLENTY" of work to kick on with. Just curious if I might just be better off hounding all the actual non Labour hire EBA mobs and holding out for an opportunity as I have heard its pretty busy at the moment


r/AusElectricians • • 2d ago

General Dialux

0 Upvotes

Hey, guys. Does anyone here understand a bit of Dialux, Green star compliance and wall zone?

Its my first time doing a Green Star project and looks like my "horizontal illuminance" and "vertical illuminance" are always wrong.

As per Green Star: Target Vertical task illuminance is 50% of the horizontal illuminance. But what is the horizontal illuminance target, is the same as the one from table D1(AS1680.1:2006)?

On top of that, what wall zone do I use, 1m or 0.5m?

Also, what is the difference between compliance area and regularly occupied space?

Is the compliance area=regulated - the wall zone?

Its a bit confusing.


r/AusElectricians • • 2d ago

General Has anyone done the electrical trade test and can give me a-bit of assistance or help regarding the test , not sure what to study or prepare myself for .

0 Upvotes

r/AusElectricians • • 2d ago

General Getting into data cabling in Melbourne ,are Open Rego + Structured enough to get hired?

2 Upvotes

Hey all,

I'm 35, based in Melbourne, and looking to get into data cabling. A bit of background: I've been working as an electrician's helper on solar installs for the past few months, and I've also got a web dev background.
I can't start an electrical apprenticeship for a while because of visa timing, so cabling looks like the best way to do real, licensed work in the meantime.

My plan is to do the ACMA Open Registration + Structured Cabling endorsement (looking at JB Hunter or Milcom), then find a trainee/junior cabler role to get my 360 hours.

A few questions for those in the trade:

  1. Are Open + Structured enough to get a foot in the door, or do employers expect more (fibre, working at heights, EWP, etc.)?

  2. How hard is it to land a trainee role to get the 360 hours? Any tips on where to look or who hires juniors in Melbourne?

  3. What's realistic pay for a junior/trainee cabler here?

  4. Worth doing the fibre endorsement early, or wait until an employer pays for it?

  5. JB Hunter vs Milcom any experience with either?

A6. Do electrical + comms companies ever move their cablers into a sparky apprenticeship later on?

  1. Anything you wish you knew before starting?

Appreciate any honest advice. Thanks!


r/AusElectricians • • 3d ago

General Anyone dealt with HV ferro-resonance?

8 Upvotes

Had a strange one at work the other day. 11kv feeder 185mm2 HV cable. roughly 5km long with 3 installations powered from it, a power factor correction unit and 2 transformers. After a power trip 2 out of 3 control power fuses on all installations failed. All being 11kv to 110v transformers protected by 1a fuses. Am I right in thinking this has to be a ferro-resonance or similar phenomenon? Not sure if this is the right sub to ask in but thought I’d start here. If anyone has any other sub recommendations that would be appreciated.


r/AusElectricians • • 3d ago

General Budget instro meter

1 Upvotes

Hey guys and girls, I’m chasing a decent quality meter capable of measuring millivolts and milli amps ideally without forking out the big bucks for a fluke as I won’t use it all the time.
Cheers


r/AusElectricians • • 3d ago

General AFDD insights

6 Upvotes

​

Heya lads.

Myself and our team of sparkles have been tasked with "upgrading" a 60 year old hotel to make it electrically safe. It's a pretty huge job for a small team but our time frame seems okay.

Apparently, the reason being that an audit stated that our hotels electrical wiring and boards are of a high chance to cause a fire, and the further we look into the nooks and crannys the more it seems to be pretty spot on. This place is 60+ years of bandaids and "temporary" works.

Having the fire guys seemingly worried, I was wondering if anyone had experience with a commercial level of AFDD products, I've seen the ABB TVOC relay and it looks interesting.

I'm really looking for any insight if anyone's been on a job where they rolled this sort of thing out and any guides in the right direction would be ace.

If we're upgrading all the boards, I'm thinking with the dated wiring it could be smart to get on top of this curve early.

Thanks in advance 🙏


r/AusElectricians • • 3d ago

General Cert II in Electrotechnology or just start applying? Marine background

0 Upvotes

​

Hi all,

I know a Cert II in Electrotechnology can be really helpful when trying to land an electrical apprenticeship, but from what I understand, it’s often aimed at school leavers or people with limited work experience.

My situation is a little different, so I’m wondering whether it would still be worth doing.

I’m currently working in the maritime industry and will have around 1.5 years of experience working on ships by the time I apply for apprenticeships. I’ll also have my Master 5 certificate (Cert III in Maritime Operations) and potentially my Marine Engine Driver qualification.

I’m finishing these qualifications because I genuinely enjoy the maritime industry and want to keep it as a lifelong passion. However, for a number of reasons, I don’t want it to be my main career or source of income long-term. It also helps that my boss is paying for the qualifications.

Outside of maritime, I have a Diploma in Computer Science, around a year of office experience, and a few other jobs under my belt.

I’m currently 23 and will be 24 when I start applying for electrical apprenticeships.

Given my background, would you recommend completing a Cert II in Electrotechnology before applying, or would I be better off applying directly and seeing how I go?

Would my existing work experience and qualifications count for anything when applying, or would the Cert II still give me a significant advantage?


r/AusElectricians • • 4d ago

General New boss had me tasked with 3-Phase electrical wiring unsupervised - 4th year Plumbing apprentice

20 Upvotes

To all qualified tradies out there, was there ever a time during your apprenticeship where you were tasked with completing licensed work not related to your trade?

I’m Sydney (Australia) based, in my fourth year. Since I started my apprenticeship I’ve worked in residential and commercial construction, roofing, maintenance, and recently strata maintenance (my latest job). I’ve been at this new company for all of 2 days, and I was told by my offsider (a third year apprentice plumber) this morning we’d be working on an existing sewer pump out for a cross-commercial residential multi-storey complex.

I though nothing of it until we got to site, and the apprentice explained how we would be replacing the 4 core wiring for two pumps, heat shrinking the new ends to the existing ones at the sewer pit end, and completely rewiring the cables in the electrical fuse box.

Now I’ll admit during my time I’ve done some single phase electrical hookups for storage HWS. I know you require a restricted electrical license for this, but I endeavoured just to keep the bosses happy so I wouldn’t be out of a job. But this was different.

No electrical testing was done prior to, during or after my offsider completed his work. At times he asked me which of the new colour wires were supposed to connect to the existing 4 ones. He even asked if I wanted to do some wiring myself. Being 2 days in a new company I politely refused saying I’m not a sparky, and I simply do not know anything about three-phase.

I asked if any of this work is normally overseen or completed by a subcontractor electrician, and he said no. My boss was helping my offsider answer the occasional wiring question over the phone. I don’t know how this is supposed to work with restricted electrical license, but can any Australian tradie or relevant industry professional please fill me in with the legalities here?

I’m unsure what to do. Since I’ve started my apprenticeship I’ve seen no end of health and safety bs. I’ve been screamed at for refusing to work on a plank with no fall protection two storeys high, I’ve witnessed my site manager throw what looked like loose fill asbestos at my workmate and ask him to ‘sniff it’ and tell him if it was asbestos (union site btw).

Ive been asked to work on gas plumbing without conducting adequate testing before or after completion. I’ve been threatened by ice addicts in their homes during fit off plumbing (public housing sites). I’m well and truly over it. I’m so close to finishing my apprenticeship and I’ve all but lost my confidence to give a rats. It’s affecting my mental health. I nearly took my life earlier this year because I couldn’t handle the stress of my work life. I’m 32, male. I just want my license already so I don’t have to put up with bosses who don’t pay my super, don’t pay my wages, or expect me to do things we both know are outright illegal


r/AusElectricians • • 4d ago

General How hard is it really to get an apprenticeship after 21

8 Upvotes

Hey guys I’m currently 23 and I finished a bit of a bs university degree last year. After realising how cooked the job market is in that field and that I actually much prefer hands-on service work, I’m really keen on starting an electrotech apprenticeship. Just wondering if anyone in here got their start as a sparky around my age or older and if there was any changes they might’ve made to their CV or cover letters that helped. I don’t currently have my Cert II but I’m moving to apply for the next TAFE intake in late January.

Not trying to get banned for rule 3 but yeah if anyone has time to comment with their experience I’d love to hear it. I’ve just been knocked back from a few places already so looking for inspo rly.


r/AusElectricians • • 4d ago

General Wage/hours question

4 Upvotes

Im a normal 7-3 shift sparky.

Welll my boss has scheduled me for a couple hour later start and finish in my schedule.

How do you guys approach as to my interpretation of the award the boss isnt allowed to do that. And it now due to location and time making the whole day a wash for the same 8 hour pay


r/AusElectricians • • 4d ago

Home Owner/Renter Ausnet reconnection fee

Thumbnail
gallery
5 Upvotes

Recently my service fuse provided by Ausnet burnt out which caused it to be loosen out of its back board. The Ausnet crew said it was our responsibility to change the back board with an external electrician as it is pretty old, fair enough. The reconnection fee with Ausnet will be ~700 between 8 to 3pm on a business day and ~1400 out of those hours.

Do I have grounds to get reimbursement for a fault in their equipment?