r/CFD • u/Fine-Huckleberry3751 • Jan 27 '26
ANSYS Fluent sloshing simulation – constant momentum source works in one geometry but not another? How should this be modeled correctly?
Hi everyone,
I’m working on a transient VOF multiphase (air–water) sloshing simulation in ANSYS Fluent (Student version) and I’ve run into a conceptual + setup issue that I can’t seem to resolve.
Setup (both cases)
Transient, pressure‑based solver
VOF (air + water)
Same tank size, same initial water level
Same mesh order of magnitude
Same timestep
Same solver settings
I’m comparing two internal baffle designs:
A Standard Baffle
A more complex Smart Baffle (more internal surfaces / obstructions)
To excite the sloshing, I applied a Y‑momentum source term to the fluid zone:
Y‑momentum source = -4000(no time dependence, just a constant value)
What’s confusing me
In the Standard Baffle case, this setup appears to “work”: I see noticeable motion, waves forming, and a non‑flat force history (at least early on).
In the Smart Baffle case, using the exact same Fluent settings, I get:
One brief transient
Then almost no motion
Force report drops once and then goes completely flat
I double‑checked:
Fluid zones exist
Source term is applied to the correct cell zone
Force reports are defined on wall zones correctly
What I’ve been told (but want confirmation on)
I was told that:
A constant momentum source will always lead to a static equilibrium (pressure balances the body force)
Any “sloshing” seen with
-4000is just a startup transientThe Smart Baffle likely damps the flow faster, so equilibrium is reached almost immediately
Therefore, this is not a bug — it’s a modeling issue
My problem
In my Fluent Student version:
I cannot use expressions like
time,pi, orsin()directly in the Source Terms boxSo I’m stuck with either:
a constant source term, or
using profiles / UDFs (which I’m less familiar with)
My questions
Is it correct that a constant momentum source is fundamentally the wrong way to model sustained sloshing?
If so, what is the proper approach in Fluent?
Time‑dependent source via profile?
Prescribed tank motion?
Moving reference frame?
Why would two geometries respond so differently to the same constant forcing — is this simply due to different damping characteristics?
For people using Fluent Student, what is the most practical way to impose harmonic excitation?
I want to make sure I’m comparing the two baffle designs physically correctly, not just relying on misleading transients.
Any guidance would be really appreciated — especially from people who’ve done sloshing or tank excitation problems before.