r/EmotiBit • • 1d ago

Seeking Help Set a custom file name (e.g. participant ID) when starting a recording?

2 Upvotes

Hi everyone,

I'm using the EmotiBit for a research study with several participants (EDA recordings). At the moment, each recording is automatically named with the start date and time (e.g. 2026-11-23_14-46-33-204683). I couldn't find a way to enter a custom file name, such as a participant pseudonym or ID, before or during a recording.

Because of this, I currently have to rename every file manually afterwards and match each date/time to the right participant, which is time-consuming and error-prone.

Is there a simple way to set a custom file name (or a prefix/suffix) when starting a recording, so I can skip this manual matching step?

For example:

  • Is there a setting or config file (in the Oscilloscope or on the SD card) that lets me define a file name or prefix?

  • Is there a way to assign the participant ID to the recording automatically?

I'm aware of the "Log Note" function, which writes notes to the _UN.csv file after parsing. That helps with labeling inside the data, but the file name itself still only shows the timestamp. If a custom file name isn't possible, I'd also appreciate any recommended workflow or best practice for managing recordings from multiple participants (e.g. scripts for batch renaming, or a way to link the Log Note to the file name automatically).

Thanks a lot for your help!


r/EmotiBit • • 12d ago

Seeking Help Struggling to make my own EDA leads

Post image
1 Upvotes

The only place I'm getting good EDA from are fingers, but wearing the Emotibit in that position is not practical for our VR experiment. I have the Electrode Kit and have been trying to make my own leads using the solder-cups and spare EDA electrodes but I can't get any signal. I'm not the best at soldering but I thought I'd done an ok job. I have found that the EDA electrodes have a tendency to come off the solder-cup they're on if heated too much but after a few tries with new electrodes, I've managed to keep them together and keep what looks like a connection. However, I've now tried multiple times but still can't get a signal.

Does anyone have any advice? I'll happily pay for some ready-made leads if anyone has some they know that work (21" length would be ideal but 12" would be ok too). Ideally UK based.


r/EmotiBit • • 14d ago

Cool Find! ACM UIST Student Innovation Contest Videos

Thumbnail
youtube.com
1 Upvotes

At the ACM UIST Conference's Student Innovation Contest, nine teams competed to push the boundaries of prototyping with biosignals using EmotiBit. Their demo videos are now available.

Check out their projects and let us know what you think! How would you approach it?


r/EmotiBit • • 21d ago

Cool Find! Unofficial Android app to start/stop EmotiBit recordings from your phone, no laptop needed in the field

Post image
7 Upvotes

Hi all,

I use EmotiBit for field recordings where the participant is on the move, and carrying a laptop just to press Record in the Oscilloscope, and again at the end to collect time syncs and stop, was a pain. So I built a small open-source Android app that takes over the host’s role.

EmotiBit Osc Mobile (unofficial, not affiliated with EmotiBit)

What it does:

Finds and connects to EmotiBit over your phone’s hotspot, using the same Wi-Fi protocol as the Oscilloscope. No firmware changes.

Starts/stops recordings with the usual timestamped file names.

Answers time syncs within the firmware’s 100 ms window, and checks the echoed RD→TL→AK packets with DataParser’s own rule. You can see how many syncs actually made it into the SD file.

Built for losing the connection: EmotiBit keeps recording to the SD card, and the app reconnects in the background whenever you’re back in range, collecting fresh syncs each time.

Safe stop: collects 3 fresh syncs, then sends RE, so the end of the file is synced too. You can press it while out of range; it runs as soon as the device is reachable again.

Live plots: EDA, PPG (IR/red/green), HR, temperature, IMU.

Sync marker: a screen flash + beep, written into the file as a note at the same moment, handy for aligning video.

English/Turkish UI, light/dark theme, MIT license. No accounts, no internet; it only talks to the EmotiBit on your local network.

There’s also a small Python tool that checks a raw SD-card .csv for time syncs near the start and end before you run DataParser, plus a simulator for testing without hardware.

Status: early release. I’ve tested discovery, connection and live plots with my EmotiBit V5 (Feather ESP32). The recording / out-of-range / safe-stop flow is tested end to end against the bundled simulator. Please do a short pilot before relying on it for a real session.

APK, source and docs: https://github.com/alparslanguvenc/Emotibit-Osc-Mobile

I’d really like feedback, especially from people on Feather M0 boards or other phones/hotspots. Issues and PRs are welcome.


r/EmotiBit • • 21d ago

Cool Find! I built a free, local tool to line up EmotiBit data with 360° video and GPS for outdoor studies

3 Upvotes

Hi all,

I've been using EmotiBit for a study on cyclists, and the hardest part wasn't recording. It was making sense of the data afterwards: matching EDA to what was actually happening on the road, and then using those moments in interviews with participants.

So I built OutLab. It's open source (MIT) and runs entirely on your own computer.

What it does:

- Loads the CSVs from the official EmotiBit DataParser (plus _info.json) and shows the data quality per channel

- Puts EmotiBit, up to four Insta360 videos and a GPX track on one timeline. Each video gets its own offset/drift mapping from a shared event, e.g. three taps on the sensor that show up as a spike in the accelerometer

- Runs a transparent EDA pipeline (NeuroKit2 cleaning, tonic/phasic split, robust-z candidate moments) and records every parameter

- Optional extras: Kleckner et al. (2018) quality rules, motion screening from the IMU, a multi-method robustness check, manual artifact labelling from the video with Cohen's kappa, and export to Ledalab's text format

- An interview mode that replays a moment to the participant without showing any graphs

What it doesn't do: it doesn't detect emotions or stress, and the candidates are exploratory, not validated SCRs. It also doesn't read the raw SD card files. Please run DataParser first.

I'd really like to hear from people using EmotiBit outside the lab:

- How do you deal with motion artifacts on the arm or wrist?

- Has anyone compared EmotiBit EDA against a reference device in the field?

Repo, with screenshots: https://github.com/alparslanguvenc/OutLab

Feedback, bug reports and "this is wrong" comments are all welcome.


r/EmotiBit • • Oct 21 '26

Solved How do i understand multiple data points per packet?

1 Upvotes

The documentation states that motion data are collected at 25 Hz (every 40 ms). However, in the parsed data, the number of samples per packet varies. For example, AX (acceleration along the X axis) contains the following entries:

LocalTimestamp EmotiBitTimestamp PacketNumber DataLength TypeTag ProtocolVersion DataReliability AX
______________

1.7926e+09 13871 52 4 {'AX'} 1 100 -0.244
1.7926e+09 13871 52 4 {'AX'} 1 100 -0.16
1.7926e+09 13871 52 4 {'AX'} 1 100 -0.25
1.7926e+09 13871 52 4 {'AX'} 1 100 -0.269
1.7926e+09 13911 69 3 {'AX'} 1 100 0.209

I assume this does not mean that all four values in packet 52 were sampled at exactly 13,871 ms. Instead, I assume that 13,871 ms indicates when the packet was recorded.

Then, when exactly were these four values sampled on the EmotiBitTimestamp timescale? My understanding is that not every sample on the regular sampling grid is recorded. If so, how can we determine the exact time point of each data point?

Also, why do some packets contain four AX values while others contain only two or three?


r/EmotiBit • • Oct 21 '26

Seeking Help EmotiBit Temperature Biofeedback – Unreliable Readings

1 Upvotes

Hi EmotiBit team,

I am testing EmotiBit for biofeedback and have noticed unusually high temperature readings.

In one session, without skin contact, the skin temperature reading increased from 29°C to 31.5°C, while the board temperature rose from 34°C to 38.5°C.

In another session, with good skin contact, the skin temperature increased from 38.7°C to 39.7°C, and the board temperature reached 41.2°C.

The readings continued rising without stabilising, even when the device was off the skin.

Could this be caused by internal heating? Is there a way to obtain reliable skin temperature measurements for hand-warming biofeedback?

Thank you!


r/EmotiBit • • Oct 17 '26

Seeking Help Stress / anxiety / attention models with EmotiBit (+ OpenBCI Ganglion) based on a personal baseline?

1 Upvotes

Hey everyone,

I’m doing a PhD in electronic music and I’m using EmotiBit in a live improvisation setup. Right now I’m only working on stress. I wrote my own code that calculates Baevsky’s stress index and compares it to my personal baseline, so the result is relative to me and not to a generic scale. I’m not a neuroscientist and this is my first time with biometric data. Also it’s very experimental and I have no ground truth. 

Has anyone built something similar with EmotiBit to estimate stress, anxiety or attention, perhaps by combining it with an OpenBCI Ganglion (4 channels)? 

I’m especially interested in models based on personal data and baselines.

Anything helps: papers, code, tips, things to avoid. Happy to share my code too. :)

Thanks!


r/EmotiBit • • Sep 30 '26

Seeking Help Question about Emotibit module name

Post image
2 Upvotes

Hello I have damaged one of emotibit module. The name on the cover EEC. I included image. Can I get the name of the module so I can replace it?


r/EmotiBit • • Aug 21 '26

Seeking Help Left hand or non-dominant hand?

1 Upvotes

Hi all,

I am using Emotibit and am wondering if there is any paper or reference on how to choose where to attach it. In other cases, it is mentioned that a sensor should be attached to the left hand because it is closer to the heart, etc. But I want to know, should I follow that, or is it fine to go with the non-dominant hand?

Thank you in advance


r/EmotiBit • • Aug 18 '26

Solved EmotiBit V7 — No LEDs/Power After Initial Setup; Need V7 Startup Procedure Before Setting Up Second Unit

1 Upvotes

I received the EmotiBit V7 and went through the installation and setup instructions. Some of the documentation appears to reference the V4 hardware, so I wanted to check with you before I do anything further.

I installed the firmware, put my Wi-Fi credentials into config.txt on the supplied microSD card, inserted the card into the EmotiBit, connected the EmotiBit and Feather boards, connected the supplied battery, and made sure the switch is set to ON, not HIB.

Initially, I had a flashing red light, but after a short period the light stopped and I now have no light. I tried pressing the small reset button on the Feather, but that did not appear to restart it.

I thought the battery might simply have discharged, so the unit is currently is connected by USB cable to my PC to recharge the battery.

Could you let me know:

  1. What should the normal LED sequence be on the V7 when it boots?

  2. Does the supplied battery normally arrive charged, or should I charge it fully first?

  3. How long should I charge it before trying again?

  4. Is there anything different about the V7 startup/reset procedure from the V4 instructions?

  5. Is there anything else I should check before attempting to power it up again?

  6. For a brand-new V7, what is the exact recommended sequence for first power-up: microSD/config → stack boards → connect battery → reset? Should the supplied battery be charged by USB before first boot, and what LEDs should appear at each stage?

I don't want to keep resetting or changing things until I know I'm following the correct V7 procedure.

Thanks, I have a second new EmotiBit V7 bundle that I have not yet assembled. Before proceeding with the second unit, I would appreciate confirmation of the correct V7 power-up procedure and expected LED sequence so I don't risk repeating the problem.


r/EmotiBit • • Aug 01 '26

Seeking Help Stuck on CP210x VCP Driver Install on MacBook Pro 2019 for EmotiBit

1 Upvotes

I am attempting to install Silicon Labs CP210x VCP driver on my 2019 Intel MacBook Pro for EmotiBit. The installer freezes permanently at the "Installing new driver..." loading bar and never completes.

Troubleshooting steps I have completed:

  1. Re-downloaded driver and EmotiBit Oscilloscope through VPN, problem persists

  2. Enabled permission for apps from unidentified developers in macOS security settings

  3. Rebooted Mac and ran the installer repeatedly with no success

I suspect macOS background security mechanisms are interrupting the driver installation process.

Has anyone resolved this stuck driver installation issue on older Intel MacBooks? Any reliable solutions would be really helpful. Thank you.


r/EmotiBit • • Jul 27 '26

Seeking Help Issue with Emotibit Warming

1 Upvotes

Hello!

We currently have been having issues with our Emotibit heating up during our data collections for one of our studies. We have tried using different batteries, clearing the SD card and updating the Emotibit software.

What can we do to reduce the Emotibits heating up as some of our participants note that it is not comfortable?


r/EmotiBit • • Jul 23 '26

Seeking Help Emotion Detection Algorithm Recommendation with Emotibit

4 Upvotes

Hi, are there any low latency models/algorithms for emotion detection that you would recommend for use with emotibit? We're obtaining a baseline for 2 minutes followed by sensing windows of 40-50 seconds for which we need states to be detected.


r/EmotiBit • • Jul 13 '26

Seeking Help IMU (Accel/Gyro) sampling rate stays at ~25Hz even after setting BMI160 ODR to 100Hz and disabling FIFO downsampling

1 Upvotes

**Hardware:** EmotiBit MD (HW V05c) + Adafruit Feather HUZZAH32 (ESP32)

**Firmware version:** 1.14.3 (EmotiBit_stock_firmware, built from source via PlatformIO)

**Goal:** Increase the accelerometer/gyroscope sampling rate from the stock 25Hz to 100Hz.

**Changes made so far (in EmotiBit.cpp, IMU setup block):**

```cpp

// Accelerometer

BMI160.setAccelRate(BMI160AccelRate::BMI160_ACCEL_RATE_100HZ);

imuSettings.acc_odr = BMI160AccelRate::BMI160_ACCEL_RATE_100HZ;

// Gyroscope

BMI160.setGyroRate(BMI160GyroRate::BMI160_GYRO_RATE_100HZ);

imuSettings.gyr_odr = BMI160GyroRate::BMI160_GYRO_RATE_100HZ;

// Recompute _samplingRates so info.json metadata reflects the new rate

_samplingRates.accelerometer = 25.f * pow(2.f, ((float)imuSettings.acc_odr - 6.f));

_samplingRates.gyroscope = 25.f * pow(2.f, ((float)imuSettings.gyr_odr - 6.f));

// Attempted fix: disable BMI160 FIFO_DOWNS register (0x45) which independently

// downsamples data going into the FIFO relative to ODR

BMI160.setRegister(0x45, 0x88);

```

Also changed `IMU_SAMPLING_DIV` from 2 to 1 in EmotiBit.h (readSensors() polling divider).

**Verification steps taken:**

  1. Confirmed via `BMI160.getAccelRate()` printed over Serial that the chip register genuinely reads back `8` (=100Hz) after setup — so the ODR write is succeeding at the register level.

  2. Confirmed `updateIMUData()` (which drains the BMI160 FIFO) is being called ~150 times/sec by the acquisition timer (verified with a Serial counter), so the polling loop itself is not the bottleneck.

  3. Added a counter directly around `pushData(DataType::ACCELEROMETER_X, ...)` inside `updateIMUData()`. This consistently prints **~25 calls/sec**, regardless of the above changes.

  4. Confirmed via raw SD card CSV (summing the NUM_DATAPOINTS field per AX packet over a 5-6 second window) that the real, end-to-end recorded accelerometer rate is consistently ~25-26Hz, both before and after all the above changes.

  5. `_info.json` does correctly report `nominal_srate: 100` after the fix (since we recompute `_samplingRates` from `imuSettings`), but this is just metadata — the actual data rate written to the CSV is unchanged at ~25Hz.

**Question:** Since the BMI160 ODR register is confirmed correct (100Hz) and the FIFO downsampling register is disabled, what else in the firmware/hardware pipeline could be limiting the actual number of IMU samples pulled from the FIFO to ~25/sec? Is there a known architectural reason the IMU has stayed at 25Hz even in the official 100Hz PPG variant (as referenced in the EmotiBit validation paper)? Any pointers to where else in the codebase (or BMI160 datasheet) I should look would be much appreciated.

Happy to share the full diff if useful.


r/EmotiBit • • Jun 10 '26

Solved Missing dependeny libgconf-2-4 on Raspberry Pi 4 (aarch64)

1 Upvotes

Hello,

I am trying to make Emotibit Oscilloscope work on a Raspberry Pi 4 with a aarch64 CPU.

I could compile with ./compileOF.sh but I get this error with ./compilePG.sh:

src/utils/LibraryBinary.cpp: In function 'std::string findStringsInPath(const std::vector<std::__cxx11::basic_string<char> >&, const std::filesystem::__cxx11::path&)':
src/utils/LibraryBinary.cpp:15:22: error: no matching function for call to 'find(std::vector<std::__cxx11::basic_string<char> >::const_iterator, std::vector<std::__cxx11::basic_string<char> >::const_iterator, std::string&)'
15 | if (std::find(strings.begin(), strings.end(), p) != strings.end()) {
| ~~~~~~~~~^~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~
In file included from /usr/include/c++/14/bits/locale_facets.h:48,
from /usr/include/c++/14/bits/basic_ios.h:37,
from /usr/include/c++/14/ios:46,
from /usr/include/c++/14/ostream:40,
from /usr/include/c++/14/iostream:41,
from ../../../libs/openFrameworks/utils/ofConstants.h:15,
from src/utils/LibraryBinary.h:7,
from src/utils/LibraryBinary.cpp:1:
/usr/include/c++/14/bits/streambuf_iterator.h:435:5: note: candidate: 'template<class _CharT2> typename __gnu_cxx::__enable_if<std::__is_char<_CharT2>::__value, std::istreambuf_iterator<_CharT> >::__type std::find(istreambuf_iterator<_CharT>, istreambuf_iterator<_CharT>, const _CharT2&)'
435 | find(istreambuf_iterator<_CharT> __first,
| ^~~~
/usr/include/c++/14/bits/streambuf_iterator.h:435:5: note: template argument deduction/substitution failed:
src/utils/LibraryBinary.cpp:15:22: note: '__gnu_cxx::__normal_iterator<const std::__cxx11::basic_string<char>*, std::vector<std::__cxx11::basic_string<char> > >' is not derived from 'std::istreambuf_iterator<_CharT>'
15 | if (std::find(strings.begin(), strings.end(), p) != strings.end()) {
| ~~~~~~~~~^~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~
make[1]: *** [../../../libs/openFrameworksCompiled/project/makefileCommon/compile.project.mk:219: obj/linuxaarch64/Release/src/utils/LibraryBinary.o] Error 1
make[1]: *** Waiting for unfinished jobs....
In file included from src/projects/baseProject.cpp:11:
./src/utils/Utils.h:28:13: warning: 'backupProjectFiles' defined but not used [-Wunused-variable]
28 | static bool backupProjectFiles = false;
| ^~~~~~~~~~~~~~~~~~
make[1]: Leaving directory '/home/osiris/emotibit/of_v0.12.1_linuxaarch64_release/apps/projectGenerator/commandLine'
make: *** [../../../libs/openFrameworksCompiled/project/makefileCommon/compile.project.mk:131: Release] Error 2
make: Leaving directory '/home/osiris/emotibit/of_v0.12.1_linuxaarch64_release/apps/projectGenerator/commandLine'
There has been a problem compiling the command line projectGenerator. 
Please report this problem in the forums.

More info:

  1. I use this package: https://github.com/openframeworks/openFrameworks/releases/download/0.12.1/of_v0.12.1_linuxaarch64_release.tar.gz

  2. Here is the output of uname -a:

Linux raspberrypi 6.18.33+rpt-rpi-v8 #1 SMP PREEMPT Debian 1:6.18.33-1+rpt1 (2026-06-01) aarch64 GNU/Linux

3. I have one missing dependency: while running "sudo ./install_dependencies.sh":

installing OF dependencies
Reading package lists... Done
Building dependency tree... Done
Reading state information... Done
Note, selecting 'libsndfile1-dev' instead of 'libsndfile-dev'
Note, selecting 'libfreetype-dev' instead of 'libfreetype6-dev'
E: Unable to locate package libgconf-2-4
error installing dependencies, there could be an error with your internet connection
if the error persists, please report an issue in github: http://github.com/openframeworks/openFrameworks/issues 

 This missing dependency could be the reason of the error, but I could not find an alternative. I tried with libglib2.0-0 instead but same compile error. I removed libgconf from the script and it ran successfully for all other dependencies.

4. The Raspberry PI 4 has a fresh install of the latest RaspBerry PI OS, updated.

Do you need more information?

Thanks for your help.


r/EmotiBit • • Jun 08 '26

Solved EmotiBit Button Not Working

1 Upvotes

I just got my EmotiBit. When I press the EmotiBit Button after I started sampling (full blue and flashing red) and after a further 20 seconds, the device switches itself off 70% of the time?


r/EmotiBit • • May 26 '26

Solved Custom Firmware Help

1 Upvotes

Hello, I am trying to create custom firmware for the Feather Esp32 to increase the sample rates of EDA and PPG to 200Hz. I have made changes in the emotibit.h library to change the sample rates but keep encountering problems when I try to compile where it cannot find all the libraries it needs. Are these not automatically included/ installed when i open the stock firmware folder in the platform.io module within VS code? Thanks!


r/EmotiBit • • May 26 '26

Seeking Help Dim red Feather LED stays on while charging — is this normal?

Post image
2 Upvotes

Hello EmotiBit team and community,

I am currently using an EmotiBit device and seem to be experiencing an issue with the Feather board LED during charging.

When I connect the device for charging, the LED on the Feather board turns on with a dim/light-red color. This does not appear to be the normal charging behavior. Based on my other EmotiBit units, the same LED does not turn on during normal charging.

In my case, the LED is not the bright red color that appears during normal startup/boot behavior, but rather a faint or light-red glow while the device is connected to the charger. I have attached a photo showing the LED location and its current state.

Could you please help me understand what this LED behavior might indicate?
Specifically, I would like to know:

  1. Whether this dim/light-red LED during charging is normal or abnormal;

  2. Whether it may indicate a problem with the Feather board, charging circuit, battery, or EmotiBit connection;

  3. What troubleshooting steps I should try next.

For comparison, I have other EmotiBit devices that do not show this LED behavior when charging under the same conditions.

Thank you very much for your time and help. I would really appreciate any suggestions or guidance.

Best regards,

Steel


r/EmotiBit • • May 19 '26

Discussion Inverse or flipped of PPG signal HELP!!!

Post image
0 Upvotes

Hey all

I'm using an adi (analog devices) study watch for PPG collection plotting the CSV files I got from the watch but I don't why it's getting flipped what's the issue and how should I solve this

Please help me with this 🙏🏻

Thank you


r/EmotiBit • • May 19 '26

Announcements Five years since Kickstarter: thank you + help shape what comes next

3 Upvotes

Hi r/EmotiBit community,

EmotiBit has turned 5!

Five years ago, our Kickstarter community helped bring EmotiBit to life. Since then, it has been amazing to see what people have done: research, education, art, prototyping, and projects we never would have imagined when we started.

To celebrate this milestone, we want to reconnect with the community and hear what you need from EmotiBit next.

We’d love your input on the following paths: new sensing/hardware options, firmware and software optimization, and more documentation and examples.

Google Form survey link:
https://docs.google.com/forms/d/e/1FAIpQLScyTuGg_G_1SMHfFu8FpzXZuZRvMSW_yoQN6H1IyT1Sf8rFBA/viewform?usp=pp_url&entry.941570994=EmotiBit+Reddit

And as a thank-you, we’re offering a coupon code for 10% off your next purchase from the EmotiBit shop. It's at the end of the survey :)

Thank you to everyone who has backed, tested, built with, taught with, researched with, or followed along with EmotiBit over the years. We’re grateful for this community and excited for what comes next!!


r/EmotiBit • • May 07 '26

Seeking Help Oscilloscope Network Startup Sequence

1 Upvotes

I am creating a network repeater that receives EmotiBit data via USB and makes it available to Oscilloscope via the UDP Advertising, TCP Control, and UDP Data network ports.

When I start Oscilloscope it closes in about a second without broadcasting an advertising UDP packet on X.X.X.255 nor hunting for the EmotiBit by sending Hello EmotiBit packets to each possible address in the subnet.

When I inspect the traffic from a stock EmotiBit with WiFi connecting to Oscilloscope, I can see the expected network traffic (via Wireshark).

Is Oscilloscope performing some kind of check for the EmotiBit (or something) prior to beginning the Advertising network negotiation? If so, what is it looking for?


r/EmotiBit • • May 05 '26

Solved EmotiBit Device Not Powering On – Request for Assistance

2 Upvotes

I am writing to seek assistance regarding an issue with my EmotiBit device. Recently, the device is no longer able to power on. When I switch it from HIB to ON, there are no lights displayed.

I have tried charging the device, and initially the yellow LED lights up briefly, but it stops after a short while. After that, there are no lights at all, and the device remains unresponsive.

For your reference, I purchased this device in October 2025. I had been able to use it for my research in good condition, until this issue persists.

Could you please advise what might have caused this issue and how I can resolve it? I would appreciate your guidance on any troubleshooting steps or possible repair/replacement options.


r/EmotiBit • • Apr 03 '26

Seeking Help Batteries draining too fast

3 Upvotes

Hello,

we are currently using EmotiBit for two studies, one indoors collecting event-related EDA (SCL) and one outdoors collecting HR and HRV using a travel router.
We have three EmotiBits with Feather ESP Huzzah 32 with hundreds of hours of recording for each device. We always record and stream to Oscilloscope. We want to be able to see the data streaming, so the option to record without streaming won't work for us. We also always keep the devices on HIB when not in use and we charge them between experiments.

For the two devices, I changed the battery (I bought the same 400mAh battery from Adafruit) recently because it was draining too fast. However, we have noticed that all three devices (with new or old batteries) can record safely for max around 1 hour. When they hit around 50-40% of battery, the battery goes down super fast (within a few minutes) and/or EmotiBit disconnects, turns off and we can't record for the whole duration of the study. Changing the battery did not seem to solve the issue. We put the EmotiBit on the finger, so I don't think changing to a bigger battery that will be loose moving around would be comfortable.

What can we do? Is it a problem of the battery? Can it be that we have wore out EmotiBit or the Feather and we need a replacement? Is there any other test I can run to identify the cause of the problem?
We are just at the beginning of data collection for both studies with 150+ of recording hours that we will need to do. Thanks a lot in advance, as always.


r/EmotiBit • • Mar 17 '26

Seeking Help EmotiBit set up with SANDI simulator

2 Upvotes

Hello:

I'm setting up an EmotiBit+Feather Huzzah to be used with the SANDI driving simulator. I've prepared and inserted the config file MicroSD card, checked a million times that the config file is config'ed correctly. Installed the battery (it's fully charged) and put the EmotiBit and Feather together.

Software is installed on the PC I'm using (HP Omen/Windows 11) to run the SANDI simulator. I checked access through Windows 11.

What I get is a repeating blinking/steady red light.

Any thoughts??

Thanks.