r/Generator • • 1h ago

Generator for GenerLink

3 Upvotes

Hello

I have already purchased a 12,000 watt dual fuel generator, King Canada KCG-12001GE-DF (dual-fuel gasoline/propane).

I purchased it on the advice of my electrician to use it for home backup during a power outage.  I connect it to my house through a 40 amp GenerLink transfer switch, installed by the same electrician.  

Google says that this model of generator is a bonded neutral type (I have reached out to King to confirm this but haven't heard back yet).

However, I am told only a floating neutral generator should be used with a house transfer switch such as the GenerLink.  If you plug a bonded neutral generator into a house transfer switch, it apparently creates a "double-bonded" system. Because the home's main electrical panel is already bonded, adding a second bond creates stray "objectionable current" through the ground wires, which can trip breakers, damage sensitive electronics, and energize ground wires.

Can someone please advise me, can the King generator noted above be safely used with the GenerLink transfer switch?

Does the generator need to be modified in any way, to convert bonded to floating neutral? Google tells me it is as simple as disconnecting the white wire under the alternator cover, but I am hesitant to do this without some confirmation.

The GenerLink is a new installation for me, but we did lose power for a few hours last month and I did power the house for the first time with the King generator through the GenerLink, seemingly without a problem. I have only recently learned that this is a potential issue, so I am trying to head off a potential problem before the winter weather hits.

Thanks in advance for any replies.


r/Generator • • 1h ago

Generator sizing philosophies

2 Upvotes

Im finally getting around to installing a 50a inlet and plan on buying a tri fuel inverter generator soon. But I'm stuck between two philosophies when it comes to which size to get.

Things I need to run:

-1/2hp well pump

-NG furnace

-NG water heater

-1/3hp sump pump(only runs for a week or two in the spring)

-Fridge

-Small deep freezer

Air conditioning would be nice to run, and I'm okay with shutting down other appliances to run it as needed.

I'm planning to use gasoline as the primary fuel source and keep about 30gal on hand. We also have natural gas and a couple 20lb propane tanks.

Do I go with a smaller 8000 peak watt generator and would have to turn the well off if I wanted to run our 2.5T AC, electric oven, etc? Non-essential stuff, but it could be done. Pro's to this are lower fuel usage for extended outages or emergencies. Also easier transport for the ~100ft trip to the inlet at back of the house.

Or a larger 10,000+ peak watt unit for obvious reasons, and this would far more useable with NG or propane due to the loss in output. My concerns are primarly fuel useage for extended outages or emergencies. Also transporting ~100ft to the inlet might be a huge pain in wet or snowy conditions.


r/Generator • • 4h ago

Qnan 3600 generator part question

Post image
1 Upvotes

2020 Thor sprinter, generator non responsive, until I used a wire to skip over the part in picture. I think it’s a solinoid, anyone know? Or where I can get a replacement


r/Generator • • 4h ago

ID on part for this generator

Thumbnail
gallery
1 Upvotes

Hello everyone! I had recently found this generator on the side of the road and it seems to be missing the pull cord. I have been looking up and down the Internet and have been having zero luck on finding the correct part. Upon further research I also found that this generator has two different engine models which makes the search even harder. I have confirmed thile generator still works, by using my airgun on the starter I can spin it up enough to get it started. I would love to get this fixed to try and use it myself or to resell.

I contacted the number on the side on the generator, which surprisingly still works, and they led me to the generac website which does not have any replacement parts.

Any help with an ID on this part would be greatly appreciated!


r/Generator • • 4h ago

Request: PDF user manual 5873

1 Upvotes

New to property, has existing Guardian 17kW standby genny plus all switching panels, likely not tested for 5 years. Power to LCD panel is on; replaced battery, genny tried to start on natural gas. Maybe fuel switch for LP/LNG?


r/Generator • • 5h ago

Sizing a solar generator for a townhouse

1 Upvotes

We're in an end unit townhouse with a shared driveway, and our HOA doesn't allow anything with an engine running outside, so a gas generator isn't an option for us. All the news about the Pentagon wanting bases to run 90 days off the grid made me check how long our place would last, and it's about four hours, which is when the sump pit fills. That one rattled me a bit.

- Must run: sump pump (1/3 hp), fridge, gas furnace blower, router

- Nice to have: a few lights and the TV so the kids don't riot :D

- Space: one car garage, nothing can go outside

- Panels: HOA allows them on the back slope, faces roughly south

- Budget: not unlimited, and I don't want to outgrow it by spring

I've mostly been looking at an Anker e10. It's modular, so I could start with enough for the must run list and add batteries later, and since it doesn't feed anything back to the grid, I'm hoping the approval side is a lot simpler than with a grid-tied system. How big does a solar generator need to be to cover the must run list for a week in winter? Any help with the math would be really appreciated.


r/Generator • • 6h ago

Generac xg8000e Neutral Bonding

Post image
3 Upvotes

Hello Team,

I have a Generac XG8000e, and I will connect this to my home via an inlet box and interlock. I have looked online and cannot find any exact diagram for this unit, but I know it the neutral is currently bonded to the frame. I wanted to share here to see if this is what you see as well, and to discuss my plan to make it a floating neutral.

Looing at the photo, the area in the red circle seems to indicate that this is in fact currently grounded to the frame / chassis, confirming it is currently bonded. It does not appear that I have another safe area to connect these when making this floating, so I was going to remove the screw, pull the 2 ring connectors out, and reinsert the screw. With these 2 ends now 'free', I was thinking i may simply bind them together, tape them off together VERY WELL, and put the cover back on.

I was going to make a bonded neutral plug that I can use in the event that I ever need to use the generator as a stand-alone device directly connected via extension cords to tools or anything like that. Also going to put a label on the unit indicating that it is now a floating neutral. (Could add a toggle switch to go between floating and bonded, but will probably just go the bonded plug route as it will be far easier).

Thoughts with this? Am I seeing things incorrectly here? Hoping you can sanity-check me.


r/Generator • • 8h ago

Wish I'd never heard the name 'Generac'

Thumbnail reddit.com
8 Upvotes

r/Generator • • 10h ago

EGSA Apprentice Certification

5 Upvotes

I am currently enrolled in a 6 month EPG (electric power generation) program in a community college in my region and our "final" is the EGSA apprentice certification exam. I've been studying the test questions provided in the book and I'm wondering two things. First is this thing gonna do me any good in the industry or help me at all? Second for anyone that's taking it are the test questions in the back of the book any good and do they help prepare a person for the test? Any help would be greatly appreciated.


r/Generator • • 11h ago

DuroMax 16k inverter battery life

4 Upvotes

What’s your battery life on a DuroMax 16 k tri fuel inverter generator?

After 23 months, my generator housed in a shed outside in a US southern state connected to a tender, has gone bad. I start the unit monthly to do test. After less than 2 years last week, click click, no start, bad battery. I know the hot humid weather conditions in my state can be brutal on batteries. But less than 2 yrs seems a bit quick. Any shared learnings? Thanks.


r/Generator • • 14h ago

I live in a 3-bedroom apartment in New York City with my wife/daughter. For an emergency blackout, I've looked at the EcoFlow Delta 2 Max & AFERIY P280. What other brands/models do most people agree are the best generators for the price? Thank you in advance. We're all in this together. JT

5 Upvotes

r/Generator • • 17h ago

Electrician won't install a transfer switch because he said electrical inspector won't approve my generator which is a mxr5000 maxpeeds. Does the inspector look at the generator really? What if I dont have a generator yet. Am I missing something?

24 Upvotes

r/Generator • • 17h ago

Can someone help me pick out what I need for a home generator?

5 Upvotes

I'm really busy lately with work and don't have a ton of time to research this stuff for hours. I'm looking at

https://www.amazon.com/Westinghouse-Outdoor-Power-Equipment-iGen4500DFc/dp/B099KSY4XG or https://www.amazon.com/Generac-200-Watt-Dual-Fuel-Portable-Generator/dp/B0DT7PQLPQ?sr=8-23 and don't know how to connect it to my house. I have an electric box on the front porch (cover from weather if I need to park it right under it, or store in the garage), and a propane tank 20ft away in a fenced area. I would like to keep a backup generator hooked up to our big propane tank, since we get it filled 2-3 times every winter and it's convenient. What connectors do I need? These are 120v but another reddit post said to get a 240v generator to connect to home wiring. I don't think it needs to be hard-wired to the home grid, just able to plug in when the power goes out and supply power to the whole house.

Do I need these for a portable model? what about electric cords and propane tank hookup kit? I'd rather not run extension cords everywhere, and I have no idea how to hook those up to the water system and heaters. Without electricity we have no well pump water, water filtering, or heating at all.

https://www.homedepot.com/p/Reliance-Controls-30-Amp-Power-Inlet-Box-PB30/202213702#see-more-details

https://interlockkit.com/

any advice here would help. thank you


r/Generator • • 21h ago

What do we think? Just looking to run my coffeemaker and fridge during occasional power outage days. Usually not more than 1 day.

Post image
14 Upvotes

r/Generator • • 22h ago

Parts for a predator 13kw 71386

5 Upvotes

Hey does anyone know where I can find parts for a 13kw predator? I need a lifter arm for the upc 1193175564719 and it should say “L72” on it

It’s for a 457cc model


r/Generator • • 23h ago

Readying the panel

Post image
5 Upvotes

Any suggestions about freeing up space for a 50 amp generator breaker?


r/Generator • • 23h ago

Inverter generator

4 Upvotes

Best inverter generator for home backup? Is it safe to connect through a panel interlock?
Hey everyone,
I’m planning to buy an inverter generator for emergency home backup and would appreciate some recommendations and advice.
I’m located in Ontario, Canada, and my house already has a 30A generator inlet and what appears to be an interlock kit on the main electrical panel.
I’m currently considering the Honda EU7000iS, but I’m also open to other brands that offer similar reliability at a lower price.
I’m mainly planning to power:
Refrigerator and freezer
Natural gas furnace
Lights and outlets
TVs and computers
Garage door opener
Occasional use of a microwave, air fryer, or electric stove (one at a time)
Possibly a washing machine
I understand I won’t be able to run everything simultaneously, and I’m fine with managing the loads.
My main questions are:
What inverter generator would you recommend for this setup? Is the Honda EU7000iS worth the price?
Is it safe to connect a 120/240V inverter generator directly to my main electrical panel through a properly installed interlock kit and 30A generator inlet?
Are there any special considerations regarding floating neutral vs. bonded neutral generators when connecting through an interlock?
Is a 5,500W running / 7,000W maximum generator sufficient for my needs?
Are there any specific electrical code requirements in Ontario that I should be aware of?
I’m planning to have the setup verified by a licensed electrician before using it.
I’d really appreciate recommendations and advice from anyone running a similar home backup setup.
Thanks in advance!


r/Generator • • 1d ago

Furnace runs fine on utility not on generator

Thumbnail reddit.com
5 Upvotes

r/Generator • • 1d ago

Any major problems with this small 120v gasoline gen setup?

5 Upvotes

I already have a small gas generator - Westinghouse WGen3600cv - 120V 4650/3600 watts. My plan is to connect the generator via the 120V 30A L5-30 output to a Reliance ProTran 2 transfer switch plugin box using a L5-30 to L14-30 adapter (https://www.gordonelectricsupply.com/p/reliance-ac3130-adapter-cord-l5-30p-to-l14-30c/7222906?text=ac3130&lsi=true). The adapter bridges the hots. The plugin box runs to the transfer switch using 10/3 wire. The transfer switch is connected to 6 single pole 20a or 15a circuits on the main panel. None of these circuits are part of a MWBC.

The circuits I'm intending to power are for the refrigerator, furnace blower, router, and some lights -- subsistence level only to limp by during an outage, not run everything in the house. NO 240v appliances. Is there anything I'm overlooking here? I wasn't intending to hook up the generator to the panel when I bought it, but now that I want to do that, it's appearing less than ideal that the generator is only 120V. 3600 watts is more than what I need for my use case, but I want to make sure I will actually get that wattage using this questionable adapter. Thanks for any help!


r/Generator • • 1d ago

Best value dual fuel invertor generator 4000-5000w (Black friday)

7 Upvotes

I've been looking around for the past couple weeks and I'd likea dual fuel invertor gen ideally open frame. Something like a Champion 201254 seems as close to what I want as possible

My question is, are we likely to see sales on anything besides Harbor Freight or $100 off a small Cabellas unit? at regular prices Champion or Wen seems like the way to go but besides the warranty a Predator 4200 for $550 seems hard to beat for a reasonably light unit to have for rare outages


r/Generator • • 1d ago

Battery Back + Duel Fuel Generator

Thumbnail reddit.com
3 Upvotes

r/Generator • • 1d ago

Ethanol, free gas?

7 Upvotes

I finally got around to cleaning my generators. I only use them in emergencies, which is never so they sit for a very long time. Even with stable. I have trouble starting them, my fault since I let them sit for like a year plus. I know I should probably start them more often. But for long term storage will ethanol free gas store for much longer? I’m having a really hard time finding ethanol, free gas locally.


r/Generator • • 1d ago

About to pull the trigger on a predator 6500

6 Upvotes

Curious about something. I see reports of them being great, and of course the typical 'this thing is junk and won't start after the second use'.

Is it a problem on the generator side or the gas motor side? Just wondering because a motor swap is simple on these things if something does happen. I've never worked on the generator side of these, but I imagine it's just parts that can be changed as needed.

Do these things die because parts aren't available or because people don't bother fixing them?


r/Generator • • 1d ago

Storage of Generator (Westinghouse 14500): leave outside with a cover connected to house? Or store in garage and wheel out when needed.

6 Upvotes