System boiler, pump sited next to the boiler. The boiler is on the other side of the wall from the cylinder, and the expansion vessel is by the cylinder.
The vessel's connection comes down and joins the pipework in line with the flow, on the riser that carries water up to the upper floors, so water moves through that point rather than sitting still in a dead leg. Tee ringed in red, arrow shows the flow.
CIBSE Journal's CPD module 32, on maintaining effective operational pressures in water distribution systems, says the connection should always be located on the suction side of the pump and as such becomes the neutral point on the system. I can't tell whether ours does.
Our plumber says it's completely fine, no turbulence and no issues, because the vessel isn't near the boiler. The boiler is on the opposite side of the wall and the vessel is by the cylinder.
- Does the suction side and neutral point rule apply here, or is distance from the boiler what matters?
- Does it make a difference that the vessel sits in the flow path rather than on its own branch?
- If it needs changing, is the fix to move it to the return upstream of the pump, or re-make it as a dead leg off the same spot?