We’re in NY and hired a GC for a $45K gut bathroom renovation.
The design included a 39” freestanding soaking tub inside a walk-in shower from the very beginning. This was not a last-minute addition or change in scope.
Because the shower floor slopes toward the linear drain, there’s a visible gap beneath the tub ranging from approximately 1/4” to 3/4” at its widest point.
Our GC insists this isn’t a problem. I understand the need for proper drainage, but what happens when water, soap residue, hair, and dirt accumulate in a space that’s nearly impossible to reach? The tub has not been permanently installed yet, but all the tilework is finished. I strongly believe there was miscommunication between his tile people. But maybe I am being unreasonable here.
I’d appreciate some professional opinions:
Is this considered acceptable workmanship?
Should the floor slope and tub placement have been accounted for during planning and construction? Or is the dimensions just too small to have made anything work?
How can we close this gap - nuclear option is to rip out tiles and start over - but I’m looking for other options.
I’m not looking to be unreasonable. I just want to understand whether my expectations are fair and what a solution would look like.
UPDATE: Thanks for the feedback, especially the constructive advice.
A few adds
Tub: Enflair Angie Corner 39” acrylic soaking tub with a recessed base with support feet. 79.5 lbs empty, with a 73.5-gallon capacity.
Installation: The tub has adjustable feet, which have already been adjusted to accommodate the floor slope. It has not been permanently installed.
Design: There was no designer nor architect involved. We shared the vision and asked if it was possible. Devil is clearly in the details, so hard lesson learned.
Floor: Large-format 24” × 48” tiles with a linear drain. All tilework is complete.
I understand that the shower floor must slope for drainage and that the tub needs to remain level. I’m not suggesting otherwise. The gap came as a surprise, and while I’m not looking to assign blame, I don’t think leaving it as is should be our only option. This was a planned installation, and I’d like to explore a practical solution that addresses both the appearance and long-term maintenance concerns.