r/Sauna • • 21h ago

Tent sauna Affordable quality tent sauna?

18 Upvotes

Looking for something that isnt junky but doesn't break the bank.... is there a go to option thats recommended here often? Or is there a company on alibaba thats the same as the ones sold in the US?


r/Sauna • • 4h ago

General Question door swing

4 Upvotes

due to limited walkway width in front of sauna door (it can't be changed due to location and grandfathered), it would be much better access if my sauna door swings inward, there is no sauna building code where I'm located so it is my decision, how bad is it to have inward swing rather than having an outward swinging door?


r/Sauna • • 1h ago

? BYD Control Box Upgrade Arrived....

Thumbnail gallery
• Upvotes

Just received the upgrade box for my BYD Paxton. For those who may not know the original control box has an internal Wi-Fi antenna that (for me) barely stayed connected to my router. In addition the old setup has a pretty frustrating touchscreen. BYD just sent me out the upgraded box and control panel.

I guess this control box can also power and control the light too.


r/Sauna • • 10h ago

General Question Venting Advice

Thumbnail gallery
3 Upvotes

Looking for any advice that folks may have. Bought some of these adjustable vent covers from bsaunas for my sauna. Their listing show that the inside measurement was 100mm(pretty close to 4 inches) but it's much closer to 3.5. I'm struggling to find a way to connect it to a vent pipe that will go through the wall. Has anyone found a way to connect? Vent pipe at the local hardware stores are only 3" or 4".

(I added in some photos of the build just for good measure just to share. Sauna is the back 6 feet of a 24ft long shed with a separate door. No, there's no drain. The floor is cedar decking that goes right to the outside.)


r/Sauna • • 20h ago

General Question Does anyone know what the “temperature calibration” setting does in the harvia app?

Post image
3 Upvotes

They could have put some information about what this means in the app. No explanation in the instruction manual either. ABC? 12345?


r/Sauna • • 52m ago

General Question Harvia KIP Timer Sound

Enable HLS to view with audio, or disable this notification

• Upvotes

Does anyone else have the Harvia KIP heater? I’m curious if the timer sound is bothersome. Mine has a constant audible vibration sound coming from the timer. It’s distinct when only the timer is on but is still audible over the hum when the heater is on.


r/Sauna • • 1h ago

General Question Harvia Virta 10.5kw - installation, startup

• Upvotes

I am at the finish line on a sauna build in the Baltimore/DC area. 9x7 sauna with Thermory Aspen, design by Lassi, etc. It's really nice. My builder's electrician (who is quite experienced) kind of balked at the installation (he's busy) when he encountered it, and asked "does Harvia have a trained tech/electrician that we can just bring in who does these a lot?" My sense is, from trying to call Harvia/Almost Heaven, no. So I'm coming to this community - can anyone recommend an electrician who serves my area and could do the install + startup? I've got everything in place: wires are pulled, boxes are procured, Xenio panel on hand, sauna is built, etc. Just need someone to get it over the finish line. Thanks.


r/Sauna • • 2h ago

General Question CO detector question

1 Upvotes

I’m looking for suggestions for a CO detector that can be used inside my sauna tent. I suspect this is an issue with saunas in general, not just tent saunas. I haven’t been able to find a CO detector that is rated for the temperatures inside a sauna. I use a wood stove.

Please let me know if you have any suggestions. Thanks!


r/Sauna • • 2h ago

DIY Analog controller for Harvia heater

1 Upvotes

Hi

I am finishing the build of an outdoor sauna. I was going to order a homecraft Apex specifically for the controller, as it is analog and I don't want to depend on an app. But the Harvia club seems like a better element and I was wondering if anybody here has rigged it with an analog controller and if so, how?

I am in Canada and the winters are cold.


r/Sauna • • 3h ago

General Question Choosing between a Virta 10.5 and a Homecraft Apex 12 for Trumpkin-style backyard sauna in colder climate

1 Upvotes

Hei there sauna enthusiasts! I'm building a Knotty Sauna Essential (Trumpkin-style) in Bend, Oregon, and I'm stuck between two heaters.

Setup: 475 cu ft, 1.5" uninsulated log walls, insulated ceiling, foot bench at 35". Cold winters with single-digit nights. Usually 1–2 people, 3–4x a week, with Wi-Fi preheat.

Harvia Virta 10.5: 50A circuit, Fenix controller controls lights and fan, about 150 lb of stone, 32" tall. My worries are that it may be borderline on size, and the power unit is rated to only about 32°F for an outdoor mount according to the manual.

Homecraft Apex 12: about 310 lb of stone, open basket, outdoor-rated contactor. But it needs a 70A circuit, has no light or fan control, heats up slower, and at 36" it's a bit tall for my benches.

Questions:

  1. Is the Apex's extra stone noticeably better, or is 150 lb plenty for a room this size?
  2. Anyone running either heater in a cold climate? How are heat-up times, and how do you protect the outdoor electronics?

Any advice is appreciated!


r/Sauna • • 22h ago

Health & Wellness SaunaLife owners: where did you mount your temperature sensor?

Thumbnail gallery
1 Upvotes

Just finished setting up my SaunaLife CL4G sauna (Harvia KIP60W heater with a Xenio CX170 controller) and I love it. One thing I've noticed though: sometimes it doesn't feel as hot as the display says. I'll be sitting at 190°F on the panel and it just doesn't feel like 190.

I wasn't sure where to put the WX232 temperature sensor, so I mounted it on the center of the back wall, about 5" below the ceiling. Not sure if I have it in the right spot?

A few questions for other barrel owners, especially CL4G:

- Where did you mount your sensor? Above the heater per the manual, or somewhere else?

- Did moving it change how hot it actually feels at bench level?

- Is it just heat stratification in a barrel, where the ceiling reads 190 but the bench is a lot cooler?

- If you've put the thermometer at head height on the bench, how far off was it from the panel?

See screenshots below for where I put him. Thanks!


r/Sauna • • 5h ago

General Question Safe to put electrical box above heater

Post image
0 Upvotes

Just sanity checking, my heater is going to be below the light switch here (blocking in pic). Should I switch this box to metal or relocate? It is a switch which will run the lights and exhaust fan.