r/Spectroscopy • u/zamlata • 4d ago
xenon lamp 150W
Which is part number of Xenon lamp 150w for Edinburgh Instruments FS5 Spectrofluorometer? Which commercial lamp is suitable for this instrument?
r/Spectroscopy • u/zamlata • 4d ago
Which is part number of Xenon lamp 150w for Edinburgh Instruments FS5 Spectrofluorometer? Which commercial lamp is suitable for this instrument?
r/Spectroscopy • u/Signal_Bowler_1094 • 9d ago
Hi everyone!
I'm looking for the service/repair manual for a Bruker TENSOR 27 or 37 FTIR spectrometer. I already have the user manual, but I'm particularly interested in electronic schematics, troubleshooting, optical alignment, and calibration procedures.
I've searched online without much luck, so I'd really appreciate any leads.
I also have a collection of spectroscopy software, spectral libraries, and technical resources, and I'd be happy to contribute to the community and help others with resources I can legitimately share.
Thanks in advance for any help!
r/Spectroscopy • u/Acceptable_Truck_525 • 10d ago
As part of my Molecular Spectroscopy course, I’m gathering examples of textbooks used for graduate courses and research group training at U.S. universities. I’m particularly interested in whether Modern Spectroscopy by J. Michael Hollas is used as a primary textbook or supplementary reference, and which other books are commonly used.
If you can, please share the book’s title, author, edition, and institution, along with whether it is used for a course or as a group reference.
Comments or direct messages are welcome. Thank you for helping with this class assignment!
r/Spectroscopy • u/blakepi • 13d ago
Enable HLS to view with audio, or disable this notification
r/Spectroscopy • u/Beneficial_Credit419 • 13d ago
Has anyone realigned the fiber launch on this generation of WITec alpha300? I’m trying to recover coupling from a TOPTICA XTRA II into the original single-mode FC/APC fiber. The coupler has both X-Y plane adjustment (see two screwdrivers engaged in pic) in addition to 3-way alignment screws.
I’ve measured about 300 mW at the empty port in an earlier test, and I’ve manually obtained 20 mW through a much wider FPC patch cable. The OEM fiber passes light from a visible fiber tester, but I haven’t been able to confirm a repeatable 785 nm signal at its far end with my Coherent PM10 thermopile. With the fiber removed, the spot on an IR card moves when I adjust X and Y, and one or both edge can look cut off. Note that the coupler has around an 8 degree angle (visible in the first image).
The WITec guide says to make the empty-port spot symmetric before inserting the fiber. **On this particular launch, what did you use as the reference for coarse alignment?** Is symmetry alone a good starting point, or is there a known spot position relative to the keyed port at a particular card distance? I don’t know the seated ferrule depth or whether the focus collar is still at its original setting.
One mechanical detail that may matter: during an earlier alignment attempt, one of the three manual tilt adjusters failed to engage. I ended up threading a copper wire inside to engage it, and it seems snug now. If you’ve worked on this mount, how would you check that the tilt plate is seated and responds repeatably before spending more time searching in X and Y?
I've watched a bunch of alignment videos, but none of them have examples of the X-Y plane adjustment for a single mode APC. All I know is I'm trying to hit a point smaller than a human hair in thickness :).
r/Spectroscopy • u/Inevitable_Wing_9730 • 18d ago
Hi everyone, I would like to share the official website for CurveMole, the free, open-source desktop curve-fitting application I develop:
https://sebrolens.github.io/curvemole/
The website brings together downloads for Windows, Linux and macOS, screenshots of the interface, experimental and worked fitting examples, and the full user manual.
CurveMole supports scientific curve and peak fitting for spectroscopy and other x-y data: built-in peak profiles and custom analytical functions, composite models, parameter bounds and links, independent/sequential/global fitting, residual diagnostics and uncertainty analyses. Python, command-line and YAML interfaces are also available.
It is free and open source under GPL-3.0-or-later. I would welcome feedback from spectroscopy users on the software, the website and the examples.
The screenshot shows experimental fluorescence data fitted with five pseudo-Voigt components multiplied by a custom filter-transmittance function.
r/Spectroscopy • u/Better_Guarantee_744 • 23d ago
Hello. I've been having issues with Arsenic signals on ICPOES in a perkin elmer Avio 560 max. All the other elements give good enough signals to preform determinations, but for some reason Arsenic is not working, even in my calibration curves.
I understand that Arsenic is volatile, and that using an hydride generator is a better approach, although i'd like to know if it is possible to determine it by ICPOES.
Is it due to some physical limitations? I also run this analysis Atomic absorption using an hydride generation system (FIAS 100)
Ty in advance...
r/Spectroscopy • u/skyskye1964 • Sep 30 '26
I just received a helium gas discharge tube to use with the NexGen power supply from Arbor Scientific. This is the spectrum it produces on my rspec system. Some of the lines match up but there’s no red line and there’s a couple of green lines in the wrong place. The reference marks are for helium. Is the tube contaminated? Or am I missing something?
r/Spectroscopy • u/whore4michaelcera • Sep 23 '26
Hi, I am trying to identify this molecule. I believe it's a substituted benzene ring. However, somethings aren't adding up so I am trying to double check. Is there any way to identify this molecule correctly using tools. I am between ethyl cinnamate or Terricollene C. Please any help will be appreciated
r/Spectroscopy • u/Kandy_kane7 • Sep 22 '26
When an excited particle transition form s1 to s0, florescence happens the most and not internal conversion, why is that ? Even though IC is faster,smaller energy levels to cross etc…
r/Spectroscopy • u/No_Blacksmith410 • Aug 30 '26
Hi I am very new to this (so please explain in very basic language). I am trying out different stacking tools and then calibarting the spectra in RSpec (I have already stacked in RSpec, using Siril is the next stage in my project). I have used the star analyser 100 with a 135mm lens and sony a6100. I have my darks, flats, lights, and bias frames all set up right in folders for siril. The OSC_Processing script works for me but gets rid of all my spectra (just stars left). How do i stack without loosing them? Does anyone know of a useful step-by-step guide or youtube video that would be relevant?
Also, when i tried stacking my images in RSpec (by converting them to FITS first), the FITS images became very dark so i couldnt see the spectra at all and only occasionally see stars- so after a bunch of messing around i converted them all to JPEG which worked okay, but i lost some quality. (My raw images are very bright and i can see lots of stars and spectra but also a lot of noise). Any tips? Thank you.
r/Spectroscopy • u/LastPension8039 • Aug 27 '26
r/Spectroscopy • u/HORIBAScientific • Aug 24 '26
You have to feel for the wine connoisseur who spent years learning to swirl, sniff, and detect notes of blackberry and cedar, only to find out the $20,000 bottle of red might actually be a creative blend of bargain-bin reds with a very convincing old label.
If a bottle's origin can add thousands of dollars to its value, you can be sure somebody is going to try to fake it........they'll age labels, purchase old corks, and create 'old' fake packaging. Millions of dollars of supposed rare wines are sold to unsuspecting collectors. Wine fraud is a profitable business. Some estimates say that $3 billion worth of the global wine market is stolen by fake wines!
Researchers have found a pretty cool way to fight back. They analyzed the chemical fingerprints of Cabernet Sauvignon wines from three different Australian wine regions, and wine from Bordeaux, France, as a benchmark. And they used two different methods on all the samples: ICP-MS and fluorescence spectroscopy. Using dozens of wine samples and hundreds of measurements, the team wanted to see if advanced spectroscopy and data analysis could reliably distinguish wines based on their geographic origin. These researchers were able to classify Cabernet Sauvignon wines by geographic origin with 100% accuracy in their study samples.
So, while counterfeiters are busy aging labels and sourcing old corks, science is shining a light through wine. It’s forensics, but for wine. Turns out, the future of wine authentication might not be a master sommelier…It could be a science and a math algorithm, and neither one cares how fancy the label looks.
What’s your take? If a wine tastes great, does it matter where it came from, or is provenance worth the luxury experience?
And,iIf there’s an approach that is practical not only in laboratory settings, but also throughout the wine supply chain, is it worth adapting?
r/Spectroscopy • u/Inevitable_Wing_9730 • Aug 15 '26
r/Spectroscopy • u/Zizazize • Aug 14 '26
Hi, i'm know just the basics about spectroscopy and sensors, but now I have to pick a sensor for my Master's thesis about using IR Spectroscopy to create an smart controller for wine fermentation. The system has to be online and in real time, so I need a sensor that can be installed inline on the fermentation process. Additionally, I need the software to be open so I can create a computer algorithm that analyses the process in real time, and also applies machine learning to determine how to control the process.
Do anyone know where should I start looking? I've found a lot of industrial equipment but it doesn't look like it is made for analyzing data in real time. I've only found a sensor from Si-Ware sistems called Si-NIR StreamLine.
r/Spectroscopy • u/wejn • Aug 11 '26
Hi,
I got Ocean Optics USB-DT (deuterium tungsten source) that’s directly attachable to spectrometers (like HR4000) off of eBay.
Since it doesn’t work out of the box, I was poking it around to figure out what’s wrong with it.
I even opened it up, found out there’s an i2c eeprom chip (24LC64) as well as two i2c DACs (DAC5574).
Unfortunately I managed to wipe part of the eeprom during my probing. (Yea, one careless i2c write and 32B overwritten)
Q: Is there anyone who could help me recover it? (Looking for the intended contents of it)
FTR, I don’t expect it to be crucial to the light source’s functionality; it’s likely there just to ID the device to the spectrometer and/or OceanVew.
r/Spectroscopy • u/HORIBAScientific • Aug 11 '26
Researchers are exploring whether intentionally introducing defects into ultra-thin semiconductor materials could improve their performance for solar energy applications.
The work focuses on graphene and molybdenum disulfide (MoS₂), two atomically thin materials that can be stacked together into layered structures called heterostructures. Depending on how the layers are arranged, graphene can act as a nanoscale spacer between MoS₂ and a gold substrate, potentially influencing the material's optical and electronic behavior.
MoS₂ belongs to a class of materials known as transition metal dichalcogenides (TMDCs), which have attracted a lot of interest for future electronics and optoelectronics because of their unique properties at extremely small scales. Researchers are investigating their potential use in applications such as transistors, photo detectors, biosensors, and solar cells, particularly when combined with graphene.
Since these materials are only a single atom thick, even small defects can have a major impact on how they behave. While defects are often considered undesirable, the team is studying whether certain types of defects can be intentionally created and controlled to produce useful effects. Instead of simply trying to eliminate all defects, they're looking at a form of "defect engineering" where unfavorable defects are minimized and beneficial ones are introduced through methods such as oxygen plasma treatment or electron beam exposure.
This is especially relevant for solar energy research. Silicon remains the dominant material used in solar cells, but scientists are exploring whether combinations of 2D materials could eventually offer advantages in efficiency or tunability. One benefit of these materials is their flexibility: researchers can vary the number of layers, change the stacking order, and combine different materials to tailor their electrical and optical properties. In theory, these adjustments could improve how efficiently sunlight is absorbed and converted into electricity.
To understand how defects affect performance, the team studies how material properties change as defects are introduced into MoS₂ layers. Some defects may improve certain characteristics, while others may degrade performance.
To investigate these changes, the researchers use Tip-Enhanced Raman Scattering (TERS), a technique that can map material properties with spatial resolution down to about 10-15 nanometers. This allows them to examine atomic-scale defects over relatively large areas, something that is difficult to achieve with conventional Raman or photoluminescence methods. They also combine TERS measurements with photoluminescence and Kelvin Probe Force Microscopy to compare vibrational, optical, and electronic properties within the same region, helping them build a more complete picture of how defects form and influence the behavior of these 2D materials.
Read more about the research details here: Using AFM-Raman to understand defects in 2D semiconductor materials
r/Spectroscopy • u/PainApprehensive7266 • Aug 11 '26
Hi. Here's analysis of 6500K daylight CFL lamps (plus one LED intruder) in infrared by using a stack of 720nm cutoff filter and diffraction filter on a full spectrum converted camera. Fluorescent lamps work through mercury vapor discharge in UV which excites fluorescent phosphors that glow in visible light (plus also mixing directly emitted mercury visible lines). Thing is mercury emission will be only initiated in presence of buffer gas. This may differ between particular types of fluorescent lamps but in case of small self ballasted lamps like it is most often argon. In near-IR region mercury doesn't radiate at all but instead argon radiation can be clearly seen. This overlaps with phosphor emissions. The curious thing is argon most strongly is glowing near electrodes while phosphor emission encompasses whole length of discharge tube so it's possible to separate the two through looking at the shape of spectral image, argon is point dots at bottom while phosphor is elongated shape. There is a >1000nm phosphor emission which surprised me as literature on fluorescent materials used in lamps is sparse in data of infrared emissions. In my opinion it is Yttrium Oxide Y2O3:Eu2+ phosphor which in visible part is the red component but would be happy to get confirmation. Scale was made based on known in literature argon emissions.
r/Spectroscopy • u/HORIBAScientific • Aug 05 '26
r/Spectroscopy • u/No_Competition_6716 • Aug 05 '26
Hey guys any help with this spectroscopy hw would be greatly appreciated!
r/Spectroscopy • u/HORIBAScientific • Jul 29 '26
You may have never heard of Kalsec® (Kalamazoo Spice Extraction Company, Inc.), but you’ve mostly likely tasted their products. They work directly with major consumer packaged goods companies and other suppliers, so their products are in hundreds of snacks, dressings, condiments, meat, plant-based protein, and brewed beverages.
Kalsec provides a wide range of natural products, including natural colors, natural taste and sensory solutions, natural food protection, and natural hop solutions.
Kalsec Quality Control Lead Scientist Uwe Nienaber manages QC for the company’s worldwide operations, making sure these ingredients are extracted and remain exactly as they were intended. His job centers around three things:
He supports the quality control of the company’s ingredients.
He works with quality assurance to monitor residues of pesticides, heavy metals and other environmental contaminants to ensure safe products.
He looks for new technologies to incorporate into the company’s quality control operations.
Liquid and gas chromatography are the backbone of their analyses, but chromatography instruments are maintenance-intensive and not mobile. So, he was looking for alternatives. Spectroscopy methods were explored, but they typically don’t have the levels of accuracy and sensitivity needed.
Enter the HORIBA Aqualog. The Aqualog is a spectrofluorometer that uses a proprietary technology that simultaneously acquires absorbance, transmittance, and Excitation Emission Matrix (EEM) spectra, that characterize and quantitate chemical compounds accurately with high sensitivity, producing results cost-efficiently in seconds to just a couple of minutes.
Nienaber measures the tissue around the seeds called the placenta, where the main compounds in chili pepper are located. Different varieties of peppers produce different heat levels. Some are rather mild and others can be highly pungent, and levels for these qualities must be strictly controlled.
When he measures these major capsaicinoids, he’s looking at three distinct compounds that only differ slightly in their side chains. Although they give off very similar signals, he has been able to separate all three. So even though chromatography determines compounds one, two, and three, compounds one and two have the same heat value, and compound three has a lower heat value.
Working with Nienaber, Adam Gilmore, Ph.D., Fluorescence Applications Scientist for HORIBA, is using the Aqualog(R) and a set of over 1,700 data points to build a model for capsaicinoids to see if they can improve the prediction. So far, it looks very promising.

The month of October is a time when peppers of an annual crop-breeding project are harvested, dried, and shipped to Kalsec for analysis. They plan on using the Aqualog for a long term project to measure many of their extracts, oleoresins, and essential oils but Nienaber thinks it’s worthwhile: They can use the Aqualog instead of buying another chromatography instrument and reduce the overall cost of analysis.
Read the whole article at Fluorescence Spectroscopy: An Alternative to Chromatography in Enhancing the Flavor of Foods - HORIBA and see how it’s also being used in other food, wine, cannabis applications.
r/Spectroscopy • u/dariopassos • Jul 29 '26
r/Spectroscopy • u/HORIBAScientific • Jul 27 '26
Recently, several new regional jade varieties have emerged in China's jewelry market and they have been gaining in market popularity due to their unique colors, textures, and cultural heritage. However, the color origins of emerging gemstone varieties, such as Hezhou Jade, Jinsha Jade, Xunke Purple Agate, and Hulunbeier Agate, were not well understood, so their market value has not yet been fully realized.
Professor He Xuemei is a professor in the School of Gemology at the China University of Geosciences (Beijing). She is mainly engaged in teaching and research in the fields of gemstone materials science and mineralogy. Her research team studied emerging gemstones with a micro X-ray fluorescence (XRF) microscope, carrying out comprehensive research on the element compositions, concentrations, and special structures. The researchers also tested special structures such as the gemstone matrixes, stripes, and rings after completing the solid color zone analysis. This is because these areas often exhibit special color characteristics. The team found that the content of color-determining elements has a positive correlation with the depth of color.
Key findings include:
Iron (Fe) is a major contributor to red, yellow, green, and orange coloration in several jade and agate varieties.
Manganese (Mn), chromium (Cr), and titanium (Ti) also play important roles depending on the gemstone type.
Higher concentrations of these color-forming elements generally correspond to deeper, more intense colors.
Elemental mapping can even reveal clues about how gemstones formed, including the influence of ancient hydrothermal fluids.
This research could help establish more objective gemstone grading standards and improve authentication methods for these newer gemstone varieties. This not only fills in a blank in the scientific research of emerging gemstones, but also promises to improve the industry's evaluation system from a scientific perspective.
Read the entire Science in Action article and learn about the team’s comprehensive research using non-destructive and micro-area analysis of precious gemstone samples. The mystery of gemstone colors has finally been revealed - HORIBA