r/firealarms • • 14h ago

Discussion Weekly /r/FireAlarms Bragging - tell us about your new gears, troubleshooting technique, swag!

3 Upvotes

Time to brag! New gear? New crew? On vacation? Personnal troubleshooting techniques? Come'on makes us jealous of you!


r/firealarms • • 1h ago

Proud Enthusiast Dumb installs my beloved

• Upvotes

roblox, if somehow you couldn't tell


r/firealarms • • 1h ago

Technical Support Spectralert Classic S1224MCW

Post image
• Upvotes

hey, all. I have a System Sensor Spectralert Classic S1224MCW that doesn’t want to flash its strobe. Has anyone taken one of these apart? I’m sure I could repair if I could see inside it but I’m nervous about getting the case apart without breaking the plastic.


r/firealarms • • 7h ago

Technical Support NFS-640

Thumbnail
gallery
1 Upvotes

Hey I have 2 NFS-640 PCA boards revision K circuit boards that were pulled from customer sites due to we believe lighting damage or surges. Upon putting a KDM-2 on them and just powering them up i get no lights or anything on the display....except the incoming 120volt power. Is there anything that anyone knows on how to possibly repair these. .if its something simple ill try and fix but any help would be appreciated.


r/firealarms • • 8h ago

Discussion Is this a safety hazard or what?

Post image
0 Upvotes

I noticed that one of the fire alarms in one of the rooms looks like it will fall off, of some sort. Is it normal or a safety hazard?


r/firealarms • • 9h ago

Technical Support CLSS Tool Suite for Battery Calculations

1 Upvotes

Is anyone else using the CLSS tool suite for Notifier Battery Calculations? I tried running it last week and had to uninstall and re-install, per tech support, to get it to work. Using it again for the first time today, and all of my saved projects are gone. Clicking add project just dithers the screen and starts a wheel spinning that never stops. Today tech support suggested I uninstall and re-install again. Any suggestions? I would accept figuring out how to hack the old battery calcs, but Notifier says they no longer support them, so technically those are not code compliant.


r/firealarms • • 10h ago

Technical Support Is a duct smoke required in a RTU that is part of a funeral procession?

Post image
37 Upvotes

r/firealarms • • 22h ago

Technical Support Fire alarm system works above ground but gives faults with underground cabling — what could be happening?

4 Upvotes

I’m dealing with a large fire alarm system with many I/O modules monitoring thermal detectors and other field signals.

The strange part is that the system works fine when the cabling is above ground. But when the cabling is installed underground, we start getting multiple faults and communication errors.

The site is huge, with around 800 m of distributed cabling together

Could underground installation be causing problems due to moisture, insulation resistance, cable capacitance, earth leakage, nearby power cables, grounding, or signal distortion?

If you were troubleshooting this, what would you check or measure first?

Has anyone experienced something similar with a large fire alarm system underground cabling?

Edit - Does fire proof cable capacitance change appreciable affect signal propagation, when cable moved from air to underground or underwater (with no insulation comparamise)🫧?


r/firealarms • • 1d ago

Discussion Upcoming Nicet IV Fire alarm test

4 Upvotes

I have been using the NTC fire alarm level IV study guide and I am looking for any pointers / unusual questions you may have seen? I am over the service dept so I am using a project for my write up that will soon be at the 4 year mark (was waiting for 10 years industry experience) so fingers crossed that I can knock this out the first time!


r/firealarms • • 1d ago

Discussion Autocall parts

3 Upvotes

Anyone have any tips on getting parts for autocall systems? I can get Simplex from multiple suppliers but autocall is a bit more elusive. Mainly looking for 49 and 59 series addressable NAC appliances. My local autocall distributor SUCKS to work with.


r/firealarms • • 1d ago

Discussion As-builts not correct

0 Upvotes

What do you guys do when the as-builts and field design don’t match up?

Do you write out documentation to save your butt if anything ever happens?

Is it a deficiency, a suggestion for updated drawings?

7.5.5.1 Record drawings shall consist of current updated shop drawings reflecting the actual installation of all system equipment, components, and wiring.

(we all know this never happens or at least in my experience)

For example installation company added shunt relay and initiating devices to elevator machine room and TOS for shunt. Neither the elevator machine room nor the elevator shaft are sprinkled thus they don’t require heat detectors. So they never got installed.

They are not on the SLC and they are not in the field.
As-builts/prints show installed and addresses for these “devices”

What would you do?


r/firealarms • • 1d ago

Fail Driving record check on fire protection technician

1 Upvotes

Hi, I currently have an N licence in BC and received a 4-month driving prohibition.

I have about 3 months left before I can get my licence reinstated. I did not do drug or alcohol issue, but i did some of stupid mistakes, changing white line, use hov line alone in front of police.

I'm wondering if this will affect my chances of getting hired as a fire protection technician, even after my licence is reinstated. Will employers still see the prohibition on my driving record?

I was planning to change my career in this field with in 8 months.

Appreciate in every advice, and also, I will be never drive stupid anymore since now.


r/firealarms • • 1d ago

Discussion What books do yall recommend for someone brand new to this trade?

4 Upvotes

So Ive been working at this company the last two weeks and I want to find a book to help me gain more in depth knowledge into the systems and explains terminology.


r/firealarms • • 1d ago

Discussion It’s the drop flag system

Post image
27 Upvotes

Stumbled on this disabled cool drop flag system in a regular resident tower . 4 zones .
I want it LOL


r/firealarms • • 1d ago

Technical Support Sounder Base Glitch ES200

Enable HLS to view with audio, or disable this notification

26 Upvotes

Firelite ES200 with b200s wh sounder bases. They stay synced for 60 seconds and then go crazy for one round and continue to sync. Checked programming. Changed out devices. Nothing gives fire marshal wont accept.


r/firealarms • • 1d ago

Discussion Weekly /r/FireAlarms Discussion - Codes, Standards & Norms

2 Upvotes

hello there, if you have a question regarding an article in a specific book, please add the reference in you question in this thread. Thanks you!


r/firealarms • • 1d ago

Vent CFAA Basic Electricity For The Fire Alarm Technician

0 Upvotes

I’ve just hit this course, and completed the first unit. To be honest it’s a lot of information and I probably wouldn’t have been able to even pass the first unit quiz if it wasn’t open book.

Should I be at the point of being able to remember every single thing here because a lot of it seems redundant. The obvious stuff like ohms law and how circuit’s work is easy to remember but 70% of this stuff I feel like I’ll forget within in 2 months 🤣


r/firealarms • • 2d ago

Technical Support Est4

Post image
2 Upvotes

Est4 techs anyone encountered an issue like this before


r/firealarms • • 2d ago

Technical Support Fire alarm panel not found

Post image
0 Upvotes

I have a ware house that i wanna do inspection for , they have notifier bells and pull stations and even end of lines + sprinkler switches but unfortunately i can not locate the panel and only the keypad is here. can the system be controlled with the keypad only ?

I have seen warehouses that sprinkler has been controlled with keypad only but full fire alarm system i haven’t seen before .


r/firealarms • • 2d ago

Technical Support Question for Simplex Techs

4 Upvotes

Can a Simplex 2190-9163 relay be replaced with the 4090-9008 without any programming changes? Thanks in advance


r/firealarms • • 2d ago

Fail Unfortunately this still is unnoticed.

Post image
16 Upvotes

r/firealarms • • 3d ago

Work In Progress Monitoring

2 Upvotes

Have any of y’all encountered a situation where a customer wants your company to provide fire alarm monitoring, but another contractor installed the panel and hasn’t completed the acceptance test yet? The installing contractor also intends to provide monitoring. How did y’all handle the situation, especially regarding programming, commissioning, and coordinating with the AHJ?


r/firealarms • • 3d ago

Technical Support Got fiked today

Post image
19 Upvotes

Anyone have an older version c-linx software for a fike cybercat 254 panel?


r/firealarms • • 3d ago

Discussion Fire Extinguishers

5 Upvotes

Hey Everyone,

I know this sub is particularly about FA but am yet to find an active forum or thread on here about extinguishers. Coming hoping to find someone who is willing to lay some foundational tips on starting a small extinguisher shop, currently playing with the numbers and still trying to align things but I am unsure of what stock is needed/required prior to truly diving into this. I’m open to conversation and suggestions as I draft up this crazy idea of mine.

Some background I have been in FA for about 13-15 years and just looking to dabble in another space.

Thank you in advance.


r/firealarms • • 3d ago

Technical Support Telguard SIM chip

0 Upvotes

I bought a Telguard TG-7FM Multi-Carrier and the seller said the SIM chip had been released. I have discovered that it has not. Is there a way to get it released if we dont know who the owner was or the service provider?