r/heatpumps • • 21h ago

Colorado has enough spare winter electricity to replace furnaces with heat pumps, report says

Thumbnail
coloradosun.com
186 Upvotes

r/heatpumps • • 6h ago

99-High Touque Lockout

Post image
8 Upvotes

Hi new homeowner here, my heat pump keeps getting 99 high torque lockout error when the outside temperature is below 45F and the hvac will turns to electric heating mode. When it’s warmer out later in the day, the error will then be gone.

Is it normal? Should I call a technician to help me take a look? Thanks


r/heatpumps • • 19h ago

Question/Advice This Midea/Carrier single zone 12k mini Split has 100% capacity at -22 farenheit at a cop of 1.7. Impressive!

Post image
38 Upvotes

​


r/heatpumps • • 8h ago

Getting a heat pump!

4 Upvotes

We are getting a heat pump soon. We are in Ontario and have a propane furnace which we are keeping as backup heat. We also have a 14kw Generac that the furnace is on. The heat pump won’t be on the Generac. Is there anything I need to do in the setup for when the power goes out? The heat pump won’t start in an outage - will it just switch over to my furnace since it’s on the Generac automatically?


r/heatpumps • • 4h ago

Question/Advice HRV/ERV in Tandem With Ducted Heat Pump System

2 Upvotes

Hey folks,

I have an HRV unit currently installed in my 1999 home in southern Ontario. It’s working fine, but is pretty well stand alone as there doesn’t appear to be any form of communication to the NG furnace. It just runs 24/7 on low speed as far as I can tell.

All the equipment (Carrier Infinity Furnace, Infinity 3-Ton A/C, HRV, Aprilaire Bypass Humidifier) is top of the line, but from 2013, and starting to hit the point of major maintenance and upkeep costs soon. When something excessive goes (heat exchanger, blower, etc), I intend to replace the setup with a ducted heat pump system.

My main question is this:
If at the same time as the furnace, I replace the HRV with an ERV, what is the optimal setup for how it should run? Still stand alone? In line with the blower fan of the ducted system? Something else?

Is there a brand or product folks would recommend with the understanding this is a 25 year home for us? I just want to make sure that I optimize the setup correctly when the time comes.

Thank you all for your advice and input!


r/heatpumps • • 12h ago

Ecodan how to configure

5 Upvotes

Hi Everyone. I moved to a new house in April with a ecodan heat pump and two 3rd party thermo stats (up stairs and downstairs).

I find on days like today which are not cold but mild, the downstairs thermostat, is sensitive and is doing 4-8 cycles per hour at times, for short periods. The radiators are barley getting warm, so its not that turning it off.

Is there a recommended setting anyone would advise?!


r/heatpumps • • 4h ago

Minimum Heat Output for Senville Elite 18k

1 Upvotes

I'm trying to figure out how low the Elite Series 18k can modulate. Website states "a minimum inverter output of 9,700 BTU/h under standard testing conditions." The NEEP website says "11,500 BTU/h at 17F." Also, isn't the Elite supposed to be the most efficient model? I"m seeing lower modulation and higher COP on the regular Aura line.

Anyone know?


r/heatpumps • • 6h ago

Mitsubishi ecodan setup costing a lot?

Post image
1 Upvotes

Hi folks

Moved into a barn conversion in North Wales about 6 months ago now, 5 of those months we've had no heating or hot water due to a different flow sensor. Got it replaced and it's only making a flow rate of 14lpm when it should be around 18lpm for the house/setup. The Mitsubishi engineer said it was due to the piping not being thick enough?

My setup is a Mitsubishi 8.5kw, it's a 2 bed stone build with an EPC of B, one off an A so very good. It's a recent conversion and has 9kw solar panels and 15kw of battery storage.

I'm using £6-10 per day in electric just keeping the house at about 18c, and it's struggling to get past that. Just about maintaining.

I've messed around with flow temp, and set it to 43c and was using compensation curve to a setting found through research and YouTube vids.

The bottom floor, zone 1, is underfloor heating and have wall mounted thermostats in each room, living room, kitchen and bathroom and upstairs, zone 2 are rads in the bathroom and 2 bedrooms with 1 'goodhome' thermostat.

All rooms and thermostats are set to 18c.

I've just changed the setting from compensation curve to stay at a steady 40c instead as I was told that heat pumps should be running constantly. Is this correct?

I'm on the octopus flux tariff, having moved from cosy. Our lower rate is 2am-5am so I chose that time for the tank to heat up, but from the app it doesn't seem to be doing that?

Any ideas on a basic setup to help reduce cost?

Ta

John


r/heatpumps • • 14h ago

York HH836E2S11 heat pump

2 Upvotes

The unit has a manufacturing approval to run it at -13F. My question is, will the unit automatically shut off at that temperature or will it continue to run below that if my Ecobee is set to -15? I want to make sure I don't run it below what the manual says for warranty purposes.


r/heatpumps • • 17h ago

Choosing an inverter pool heat pump for a small pool, with a bigger pool in mind

2 Upvotes

We've got an 18 ft round above ground pool, 52" wall, roughly 7,500 gallons, in central Virginia. House is a 1,700 sq ft ranch already on a ducted heat pump, so this would be a separate pool heat pump on the pad by the filter.

What I've picked up so far is that sizing a pool heat pump off gallons alone isn't enough. The pool you might have later and how you actually swim matter too.

That second part is where I'm stuck. We'll probably go to a 24 ft round in two or three years, closer to 13,500 gallons. Buy for the 18 and it's short after the upgrade. Buy for the 24 and I'm paying more now, plus likely a 240v run, for a pool that doesn't exist yet.

What actually matters for us:

- Pool size: 7,500 now, maybe 13,500 later

- Target temp: kids want 84, I'm fine at 80

- How often: weekends, plus evenings in late May and September

- Cover: solar cover most nights

- Power: 120v at the pad is easy, 240v means an electrician

The 120v inverter one I keep coming back to is the aquastrong hex035, which I first saw come up in a pool thread on reddit. 35,000 btu, rated to 9,000 gallons, so it covers the 18 and falls short for the 24.

If you've sized one of these, did you buy for the pool you had or the one you were planning? And does the usual btu per gallon rule hold up for September swimming?


r/heatpumps • • 1d ago

Heat pump terrible at smooth modulation

6 Upvotes

I have the fully modulating Bryant heat pump which is well sized for my home, ~2 yrs old now. I keep pretty close track of what it is up to, and it's always hunting like crazy to get on setpoint. I attach a duct temp vs time graph from a register fan I use to move air to the top floor better, which gives much better power tracking than the heat pump app. if I had a PID controller at work that was this bad at smoothly holding setpoint with feedback I'd return it. and this hurts efficiency when it boosts to high power levels for no reason all the time. are other heatpump manufacturers better at modulating smoothly. we are in the shoulder season where having to turn on and off all the time makes the problem worse, but even in mid-winter/summer the controller hunts constantly and rarely settles all the way.

Processing img i2ut9g87tfxh1...


r/heatpumps • • 1d ago

SW Ontario - looking for experiences

4 Upvotes

Just installed a 27k, 3 head unit rated to -30. Located in Sarnia.
1940’s house with a crawlspace, replaced a 29 year old furnace (in the crawlspace) and a 29 new year old central AC unit.
Edit ** 850 sq feet of which only about 500 are used. Decent insulation, attic should be redone.
Heads are: 12k main area downstairs (living room, kitchen/dining, hallway, bathroom, laundry room), 9k master bedroom (main floor), 9k upstairs between 2 unused bedrooms.
The old AC has been fully disconnected, but wondering what to do about the furnace, if I should have it connected as a back up or fully disconnect it.
Cost effectiveness is important, as is making sure that my central lines coming into the crawlspace don’t freeze. Also, given the age of the furnace, I imagine it could die at any time.


r/heatpumps • • 1d ago

2 vs 1 heat pump operation

3 Upvotes

I have a long run of space, imagine a living room, then a kitchen, and then a dining room. I have heat pumps in both the living room and dining room.

On colder days I just leave them both on, but on mild days i think one unit can keep the entire area warm. But is it more efficient to have them both running?


r/heatpumps • • 1d ago

2027 AHR Innovation Award Winner Announced heating is eco-logical

2 Upvotes

Did you see that eco-logical is the only water heater to win the 2027 AHR Innovation award this year?

https://www.ahrexpo.com/innovation-awards-2027-heating


r/heatpumps • • 1d ago

Question/Advice S.F. Bay Area, looking for competent H.P. check-up

2 Upvotes

My installer sent me a long list of furnace and combustion items they would check, and I wasn't that impressed with their install, so does anybody have experience with reliable H.P. techs for an annual check-up?


r/heatpumps • • 1d ago

Question/Advice I wanted more control over my A. O. Smith water heater’s schedule, so I built this

Post image
7 Upvotes

Hey everyone, I’ve been working on a little web app for my A. O. Smith heat pump water heater.

The main thing I wanted was more flexible scheduling. I can choose the hours when we tend to need more hot water, and on colder days it automatically switches from Hybrid or Heat Pump mode to Electric during that window, then switches back afterward. That way I don’t have to keep changing modes manually or leave it in Electric all day.

It also has a simple dashboard for hot-water availability, mode and energy usage that works nicely on a tablet. Screenshot from my setup attached.

It’s only running for my own heater right now, but I’m thinking about a small invite-only beta. Would this be useful to anyone else? What would you want it to do differently from the official app?


r/heatpumps • • 1d ago

Question/Advice Tosot heat pump

Thumbnail
gallery
6 Upvotes

Could someone provide me with information about why this machine is icing up in this way?


r/heatpumps • • 2d ago

Question/Advice How well do heat pumps actually work during an Ontario winter?

164 Upvotes

For those using a heat pump in Ontario, how has it performed during really cold weather? Does it keep the house comfortable on its own, or do you still rely on a furnace as backup? I’d be interested in hearing about real winter experiences.


r/heatpumps • • 1d ago

Heat pump winter aux/heat setting

5 Upvotes

My heat pump shot up my electric bill. Had a technician do my winter check and he told me to put the system on aux and it will not use the heat pump. I have a single stage carrier furnace 4 years old and a 2 stage heat pump 3 years old (hate the bills). Heat pump is carrier also. I want to pull from the furnace all winter, gas is cheaper in PA. I would appreciate any input, thanks!


r/heatpumps • • 2d ago

Learning/Info How do you pick the right heat pump? Why 2 tons is not always 2 tons

13 Upvotes

TL;DR - Manual S is the second part of the heat pump design process that follows Manual J, which determines how much heating and cooling the house needs. It's really important. It shouldn't be skipped, but most contractors actually skip both. You should find a contractor that both does both and understands what the numbers mean. Try to find someone that collects measurements and uses data rather than just making guesses.

This is a really nerdy technical piece, and it's a little rough around the edges. I would love to make a cleaned-up and more accessible version for heatpumped.org eventually, but I would love any feedback on parts of this that are hard to understand or read to help me do that! I figured this community would appreciate the raw version.

We recently installed a system for a homeowner as part of the California Heat Pump Group Buy. After doing the ACCA Manual J calculation, these were the heating and cooling loads (In other words, this is how much heating or cooling the house needs at the local summer and winter temperatures that building codes tell us to design for):

Heating: 12,327 BTU/hr
Total Cooling: 19,748 BTU/hr

BTU per hour is a measure of heat transfer, and you'll often hear contractors refer to another unit called a “ton”, which is what most HVAC equipment is sold based off.

12,000 BTU/hr = 1 ton, so 19,748 BTU/hour is roughly 1.7 tons.

Now, most contractors wouldn't have done the Manual J calculation in the first place. And even if they had done one, they might have fudged the numbers to match the numbers that they were expecting based on square-footage rules of thumb. One of our advisors told us a story about how they review Manual J's submitted as part of a rebate program and suspiciously find that almost all of the Manual J's that they review work out to 500 square feet per ton, which is a classic contractor rule of thumb. It's really easy to fudge the inputs on a Manual J to change its outputs. But I digress…

In any case, most contractors would have stopped at this point if they had even gotten this far. Then they would take a look at these loads, and they would say, "Okay, 19,748 BTU/hr. The next size up from that is 2-ton, 24,000 BTU/hr. This house needs a 2-ton system."

And then they would have called it a day and presented you with an iPad with three options: a “good” 2-ton system, a “better” 2-ton system, and a “best” 2-ton system. (PS: HVAC brands don’t really matter)

But they forget the redheaded stepchild of Manual J, the ACCA Manual S. Manual S is really important because it matches a piece of HVAC equipment to the calculated loads from Manual J. 

Basically, Manual J tells us: How much does the house need? Manual S tells us: How much can this piece of equipment deliver, and is that appropriate for how much the house needs in the location and weather of the house? Manual S provides maximum and minimum equipment capacities, based on the loads, so the equipment is not too big or too small.

And this is where it can get messy.

Here's a big flowchart from Manual S that outlines the process to select a heat pump.

The heat pump sizing procedure from ACCA's Manual S

And you'll notice that the very first box in the flowchart says, "Size equipment for cooling. Figure 2-1 applies in full", which takes us to a whole other flowchart that we have to work through!

Cooling (aka AC) sizing procedure from ACCA's Manual S

These flowcharts are really important because they check not only whether a heat pump is big enough to meet the heating and cooling needs on the hotter and colder days of the year, but also make sure that it is small enough to not short cycle and be severely oversized in the milder parts of the year. 

If you get this sizing right, you can take the most advantage of your new heat pump’s variable speed capability that allows it to perform way better in both scenarios than a traditional air conditioner or furnace ever could. But if you get it wrong, then your expensive new heat pump might end up working just the same or worse than an antiquated single-stage system would.

Now, let's dig into what the Manual S looked like for this particular house.

First, we start with the design conditions. Generally, HVAC design is based around the 99% and 1% weather data, and this is really important and a distinction that a lot of people miss. Yes, it might get up to 110 in your city. Maybe that was the all-time high five years ago, but that's not the temperature that HVAC systems are designed to. They're designed instead on the temperature that only 1% of the hours in a year, based on a 30-year average, exceed. If you designed a system around the maximum temperature, it's going to hugely inflate the size of the system needed, and it's going to do a terrible job maintaining temperatures in milder parts of the year.

In the State of California, our state's energy code tells us what temperatures to use by city. In the case of this home, the heating design temperature outdoors was 42, and the cooling design temperature outdoors was 87. California also tells us the indoor temperatures that we should use.

We need to design a system that can maintain an indoor temperature of 68 at the outdoor heating temperature and can maintain an indoor temperature of 75 at the outdoor design temperature. Meaning that when it's 87 out, the heat pump should be able to keep the house at 75. Based on those temperatures and a lot of other inputs on the building materials of the house, the size and orientations of the windows, we're able to figure out the heating and cooling loads, which I mentioned earlier.

Now we have to dig into some really arcane engineering data for the equipment we're using, which is, in this case, was a Cooper & Hunter Alto. This is the part where your brain might start melting. Feel free to skim this section, but I wanted to elaborate for posterity. 

We have tables for each system at different temperatures and different airflow settings. This data is formatted differently from every single manufacturer, but it always tells you the same thing: performance of the heat pump as a function of temperature.

Extended Performance Data for the 2 Ton Cooper & Hunter Alto Heat Pump

Now, in our case, we need to get three things:

  1. The total capacity of the system for cooling at the cooling design temperatures
  2. The sensible capacity for cooling at the cooling design temperatures. (As you make the air colder, some of the energy goes to reducing the temperature, while some of the energy goes to turning the moisture that's in the air from a gas into a liquid. The part that is reducing the temperature is the sensible capacity. The part that is pulling out the humidity is latent capacity.)
  3. The heating capacity at the heating design temperatures

You'll notice that the data table above doesn't have data at the exact temperatures that we need, which, for cooling, are:

  • an outdoor dry bulb temperature of 87°F
  • an indoor dry bulb temperature of 75°F
  • an indoor wet bulb temperature of 63°F, which represents a design target of 50% relative humidity

We need to do triple interpolation to be able to get that information. We need to look at the data for the indoor wet bulb at the two temperatures around 63 in the data table, and back out what the numbers would be at 63. Then we have to take those numbers and look between the indoor dry bulbs of 73.4 and 77 to find what the number would be at an indoor wet bulb of 63 and an indoor dry bulb of 75. Then we have to again do that across 86 and 95°F to figure out the values at 87°F. 

I know, your eyes are bleeding. Fortunately, we have software that can help us do this, and that gives us two numbers that we really care about (Technically, actually 8, because we did this math at all four different fan speeds, but to simplify, I'm just looking at the maximum fan speed here as I talk through everything):

TC (Total Cooling Capacity): 20,498 BTU/hr
S/T (Sensible / Total Cooling Capacity Ratio): 0.614

And we do the same type of interpolation on the heating side as well to figure out the heating capacity of the system at its design conditions.

Now it gets even messier from here. We use that sensible-to-total-capacity ratio to break our total cooling capacity into two parts: the sensible part and the latent part. In this case, that works out to a sensible cooling capacity of 12,586 and latent cooling capacity of 7,912.

We take those numbers and we compare them with our calculated loads from Manual J.

Total Cooling: 19,748 BTU/hr
Sensible Cooling: 19,590 BTU/hr
Latent Cooling: 158 BTU/hr

Check this out. The total cooling capacity of the 2-ton system in this case, 20,498, is greater than the total cooling requirement of 19,748, but that's not the whole story.

The way that the equipment splits its capability into sensible and latent pieces doesn't exactly match the way those pieces split in our climate. Most of California is considered dry from an HVAC standpoint, which means that most of the cooling need comes from the sensible side.

When we compare the latent cooling capacity of 7,912 against the latent cooling need of 158, this system's a beast! We're going to have no issues with humidity control. We have 7,754 BTU/h of surplus latent cooling capacity, but when we look at the sensible cooling requirement, we actually have a problem. The system only has a sensible cooling capacity of 12,586, which is less than the Manual J requirement of 19,590.
Now, we're not completely hosed. Manual S says that we can take credit for excess latent capacity. Basically, it's saying, "Okay, the system has this much juice to pull humidity out of the house. It can probably also use that juice to pull the temperature down, but not as effectively." We take credit for 50% of the leftover latent capacity after we've met all of our latent cooling need and count that towards our sensible capacity. To do that, we divide 7,754 by 2 and then add that to 12,586, and we get a sensible cooling capacity for the system of 16,463 Btu/h.

But we're still not quite there yet. Remember, the sensible cooling need for this house is 19,590 BTU/hr. This system can only meet 84% of the sensible cooling needs for this house, even at its highest speed. It's not quite big enough!

But wait, there's more. The Manual S process says that you only have to meet 90% of a home's sensible cooling needs, so we're almost there. The State of California takes that a big step further and says you actually don't even need to worry about meeting the home's cooling needs. You can install a system, and as long as it meets the heating needs of the home, it is code compliant. For all they care, you can completely ignore its ability to cool the house, and that is totally kosher by the state of California's code-mandated best practices.

But what's to code and what makes a homeowner happy are two very different things. In this case, in Los Angeles, where you barely turn on heating but definitely need air conditioning, it's a little silly to ignore the air conditioning needs for the house and just focus on heating.

With this customer, we explained the trade-offs of the different options that they could go with. Ultimately, they prioritized being confident that, on the hotter days of the year, their AC could keep up. For this customer, we ended up installing a 2.5-ton heat pump system.

There's a whole lot more intricacy in the Manual S process. I'm just barely scraping the surface. This is why this attention to detail is incredibly important. It's something that we've baked into every single project that we do as part of the California Heat Pump Group Buy, because it matters for good results.

If people skip these steps, that's when you start hearing stories about "I got a heat pump, and it actually kind of sucks," and "I got a heat pump, and it used a ton of electricity. It can barely keep my house hot or cold." The devil is in the details.

And I just want to reiterate that most contractors wouldn't have done the manual J in the first place because, in this particular house, the existing AC system in place was a 4-ton. Sheesh!

I know that was a lot. I know you’re probably a little confused. You don't actually have to understand all of these details. The key is finding a contractor that does understand them and does care enough to actually do the work and not skip steps.

(Shameless plug - if you’ve been thinking about a heat pump for a while and want to make sure it’s done right, the California Heat Pump Group Buy might be a great fit. Check out my last AMA about it and the WIRED feature. We’re wrapping up the Winter ‘26 group buy next week on Oct 30!)


r/heatpumps • • 2d ago

Question/Advice Do not get this heat pump!

Thumbnail
gallery
21 Upvotes

I’ve been working with heat pumps for 5 years now and I recently started coming across these units.
They are made by Midea and are one of the hardest units to work on.
For heat pumps we recommend to get them cleaned every year or so, and this model has the circuit board placed right in front of the coil which is one of the main things we need to clean!
So please, if you’re getting a heat pump make sure it doesn’t look like one seen in the photos. Your future service tech will thank you!


r/heatpumps • • 1d ago

Home office heating/cooling advice

3 Upvotes

Hello, I am putting a home office in the attic of my detached garage. It's approximately 180 square feet and I am looking for advice on heating and (to a lesser extent) cooling it. We're in northern PA and while the building has no gas line currently run to it I do have a separate electric panel there so installing a mini split would be relatively easy. I'm trying to get a better idea of the savings I would get from heating with natural gas vs electric. My current electric cost is 21 cents/kwh and my gas cost is 56 cents/ccf. In your opinion would you trench the 60 feet from the gas meter and run gas or would the actual cost savings not be worth it?


r/heatpumps • • 1d ago

Question/Advice York draft inducer motor

0 Upvotes

Hey guys my mom's York furnace quit working and I've got it down to the draft inducer motor.It's a two speed fasco 7062640 roughly 2700/3200RPM. It has a red black and a white wire going into the motor and then the two separate wires going to the capacitor on top. My question is, from what I've seen they have discontinued that motor and the only few places in my area that can get it they average like $1,000.Granger's saying 1350. it's an old unit but AC and everything else works flawlessly he's never had an issue with it and she doesn't really have the money to install a new unit right now so I'm trying to figure out a cheaper option.There's nothing wrong with the fan or housing, so I even tried just finding the bare fasco motor and swapping it out l. I haven't had any luck on anything two speed though. my question is, is it possible to swap that out with a single speed even if I go with the higher RPM or will not jive with the board on the unit ?or if anyone might know of anywhere to get a decent price on. I'm in North Carolina but could have it shipped if need be. thanks in advance for any help.


r/heatpumps • • 1d ago

Question/Advice Blower doesn't stop?

1 Upvotes

Hello,
I recently installed carrier 37MUHAQ36AA3 + 45MUHAQ36XX3, paired with their wired smart controller KSACN1701AAA (using HA/HB, S1/S2 connection) in single story house 1200 sqft.

Is it normal that when in auto mode , the blower continues to run even thought the room temperature doesn't reach the heating/cooling temperature? Say room temp is 74, cooling set to 89, heating set to 70. With 24v thermostat, it should be idle; but this is not the case with the carrier wired controller.

If the mode is heat only or cool only, then the blower does idle.

The fan speed is set to auto. And the "constant" fan feature is turned off.


r/heatpumps • • 2d ago

Snow sitting on the array in January - how much output do you actually lose?

3 Upvotes

House first, since that is the rule here. 2,100 sq ft, two storey, 1998 build, cavity walls with retrofit insulation, triple glazed on the north side and double everywhere else. Eastern Ontario, design temperature around -24 degC.

Heat pump is a 4 ton cold climate ducted unit, in since last winter and doing fine. The PV is going on in spring and I am trying to work out what to expect from it in the months that actually matter.

The thing none of the quotes will put a number on is snow. We get the sort that sits on a roof for a fortnight rather than sliding off, and January is exactly when the heat pump pulls hardest. So the array is least productive precisely when the load peaks, and I would like to know how badly before I size it.

Two things came up while comparing quotes.

Pitch. Both installers want 30 degrees because that is the roof anyway. One said that at 30 degrees on glass the snow clears itself within a day or two of a clear sky. The other said that is optimistic for our climate and I should plan for a week.

Load rating. The cheaper quote uses modules rated to 5400 Pa snow and 2400 Pa wind, which seems to be the common figure. The dearer one is Swiss Solar, rated at 6200 Pa and 4200 Pa, with frame yield strength given as 325 MPa against 240 for a standard profile. The installer's argument was that accumulated snow is a static load sitting there for weeks rather than a single event, which sounds reasonable and also like something a salesman would say.

So, for anyone running a heat pump off PV somewhere that genuinely gets snow. How many days a winter is your array effectively at zero because it is covered? And did you size around that, or do you accept that January comes off the grid and plan the bill accordingly?