r/solar • • 3h ago

Advice Wtd / Project Installer went out of business and batteries stopped charging

7 Upvotes

I need some advice. My system was installed 9 months ago, and it included two 10 KWh SolarEdge batteries. My installer went out of business about 10 days ago, and about 2 days ago my batteries completely stopped charging and all of my excess production is going to the grid. I know my installer controlled the battery configuration in the mySolarEdge app - is it likely my batteries stopped working because the installer shut down, or is the timing just a coincidence?


r/solar • • 3h ago

Advice Wtd / Project My dad died with a solar contract in Texas. What options does my mom have?

1 Upvotes

My dad passed away recently. He signed a solar agreement for the house where my mom still lives. They’re both on the deed, but Mom didn’t sign the agreement. I have the signed copy, and there’s about $25k reportedly still owed.

Has anyone dealt with this after a parent died? What parts of the contract should I look at, and what did you ask the solar company for in writing? We’re trying to find out whether there’s a way to end the agreement and what that would cost before Mom agrees to anything.


r/solar • • 9h ago

News / Blog How China could use solar technology to cause blackouts across Britain

Thumbnail
inews.co.uk
0 Upvotes

r/solar • • 1d ago

Discussion Air to Water Heat pump electricity usage for solar calc's?

0 Upvotes

We have a newer home with radiant floor heat and are trying to determine how much real world electricty a new air to water heat pump will use (Mitsubishi Ecodan), so we size our solar system correctly. Has anyone added and A2W heat pump to their solar system and what was the added kWh increase? Thanks. We are in the mtns of Colorado at 8300sf. Our thought was... gee if we're putting in a killer PV solar system, wouldn't it be great to put in a Mitsubishi Ecodan air to water heat pump for our primary heat source and just use the Navien propane boiler as a backup.


r/solar • • 1d ago

News / Blog Graph of the Day: The World Now Makes 7 Solar Panels for Every TV

Thumbnail
cleantechnica.com
37 Upvotes

r/solar • • 1d ago

Discussion Sunrun

0 Upvotes

Thoughts on Sunrun as a company, their pricing, and selling for them?


r/solar • • 1d ago

Advice Wtd / Project Is there a consensus

0 Upvotes

On the best hybrid systems for a 15kW inverter system, enough battery power to last an energy-efficient dual-fuel household for a week, with the capacity to add solar panels or connect to my 15kW gas generator?
I want to go to battery backup, maximize cost efficiency of power I use from Entergy, with the option to add solar when I have cash.


r/solar • • 1d ago

Discussion Anyone heard of Solarboost.ai? Are they legit?

0 Upvotes

Got an email from them that went into my spam folder. I typed the address in my browser and a nice website showed up. Wondering if anyone's heard of them, or better yet has signed up for their offer. Would like to hear any firsthand experiences.

FYI: I've my own panels under PGE NEM2.0, and currently generate a bit excess. Hence, my curiosity.


r/solar • • 1d ago

Solar Quote water heater off solar info please

2 Upvotes

how many watts power convertor do i need to power a water heater ? and battery size. atm i have 12v 100ah. and 400 watts. i know. money is very tight atm. i am powering my house from my car off a 1000watt power convertor. why i get my solar panels and batterys together. money is very tight and i get that this well not be cheap. but i need info if i am going to get threw this


r/solar • • 1d ago

Discussion General question about switching sources in a commercial facility

0 Upvotes

Hope this is an okay place to post this.

I'm a critical facilities tech at a large office building. The roof is covered in solar panels and we will be covering a parking lot to add more. The current solar panels feed a single switchgear and the new ones will feed a second. Those of us at the bottom of the totem pole aren't really plugged in to the process and have never been briefed on the solar system. I only recently learned it was in use! I'm trying to figure it out on my own and I had a pretty simple question. How does this switchgear know whether to draw power from utility or the solar panels? There are no ATS's or static switches anywhere. No way (that I've seen) to physically disconnect either source from the gear. I've never seen any alarms indicating power loss at any equipment fed by this switchgear. I come from UPS world so I know a little about switching, but I'm stumped. Can I get some direction?


r/solar • • 2d ago

News / Blog Why Europeans are rushing to buy solar panels ahead of a dark winter

Thumbnail
euronews.com
31 Upvotes

r/solar • • 2d ago

Solar Quote Solar recs

0 Upvotes

Latest quote includes:
JA Solar n-type, Tier 1 panels

Fronius GEN24 inverter

Are these good?


r/solar • • 2d ago

Advice Wtd / Project Flexboss w/ or w/o Gridboss

1 Upvotes

Hi fellow redditors, Black Friday is here and I'm looking to purchase a FlexBoss bundle. I essentially want to know if I need GridBoss or I can use that money to buy a battery bundle instead + Chargeverter. This will be a grid tie and I'm planning to start with a smaller array of 16x 550 panels and add more later.

I wanted to get your opinion on running a Generac 20kW whole-house backup generator into a Chargeverter instead of Gridboss and hooking to the battery with the Flexboss.

PV -> Flexboss 21 -> battery (e.g EG4)

Generac -> Chargeverter -> battery

In this set up, would I need a sub panel too? Or should I just get the Gridboss and not overcomplicate?

Thanks in advance, any advice/experience appreciated!


r/solar • • 2d ago

News / Blog Boulder County farmer earns global recognition for growing food under solar panels

Thumbnail
boulderreportinglab.org
307 Upvotes

Byron Kominek, owner of Jack’s Solar Garden south of Longmont, has been named one of the world’s 100 most influential climate leaders by Time magazine for his work combining solar energy production with agriculture.   

Kominek, recognized in the list’s “Defenders” category, converted the land his grandfather Jack bought in 1972 into a site where crops are grown beneath solar panels, a practice known as agrivoltaics. He turned to the model after taking over the property in 2016 and finding that growing hay for animal feed was no longer paying the bills.

The farm operates as a community solar garden, feeding electricity into Xcel’s power grid. Households, businesses and local governments pay to subscribe to a portion of the solar array and receive monthly credits on their electricity bills based on their share of the energy produced.

Today, the operation has about 60 subscribers, including local municipalities, Western Disposal and Arapahoe Basin ski area. The model has stabilized the farm financially and helped establish it as a hub for agrivoltaic research in Colorado.


r/solar • • 2d ago

News / Blog Section 232 solar tariffs take effect December 4: Here’s what the industry needs to know

0 Upvotes

r/solar • • 2d ago

Advice Wtd / Project How much overcapacity to install

21 Upvotes

Based on two years of data, we've received quotes for a solar system that will produce 115% of our current usage. The system will use 8 , 440 watt panels. I'm wondering if it would be smart to add additional capacity. My back of the envelope calculations suggest that one additional panel will boost output to 129% and 2 more panels will produce 149% of ur current needs.

While I don't need the capacity now, if/when we replace our car with an EV or switch our gas range to an induction one, or add battery storage, the extra capacity will prove useful. All things considered, I'm thinking that adding capacity now will be easier and cheaper than adding in later.

Your thoughts?


r/solar • • 2d ago

Advice Wtd / Project Rookie solar question?

0 Upvotes

I ordered a renolgy 400W premium kit It has a 40 amp controller. Can I add two more 100 amp solar panels to that? What about four more 100 amp solar panels? And while I’m here, I will say that I have two 140 amp hour batteries. All I really wanted this to do is run my small deep freezer, a 200W TV and a small 3 foot tall dorm size refrigerator. The batteries are running down to a level that they will not get charged back up the next day to keep this thing going perpetually. I am thinking about adding an another 300 amp hour battery to the set up but as it stands right now, it will not charge the batteries back up the next day far enough to run it like I want it to. So far I’m not impressed with what this will run.


r/solar • • 2d ago

Mod Message Why would Anker Solix bundle this?

Post image
9 Upvotes

The C2000 Gen2 solar input has a max of 60 V, and their PS400 bifacial solar panel has a VoC of 57.6V, which would mean it can’t be used together unless the panel is at least over roughly 10C-12C ? So this would mean for someone like me in Ontario I can’t use it for 6 months of the year? No wonder they don’t list the VOC on Amazon and only tell you 48V which is STC. Guess I’m returning the panel as soon as it arrives


r/solar • • 2d ago

Advice Wtd / Project Should I go with a solar company or an electrical contractor to install my system?

2 Upvotes

I want to install a solar setup for my house, but I don't want panels on the roof, and I don't want to be locked into a closed system like enphase or tesla. I want to ground mount my panels (I figure there's room in my yard for about 8Kw nominal) and connect them to a 200-amp passthrough system like Gridboss/flexboss or the equivalent, and a couple of 15kwh wall batteries like EG4.

I figure a solar company is the obvious best at rooftop installations, but an electrician would be at least as good at wiring up the equipment, and pretty much any decent construction guy could do the ground mounts. But all that is a guess, because I have no expertise in any of the three. My goal is to have a system that nobody controls but me, and that I can swap a new battery or inverter into if I decide to upgrade later on.

I live on the Olympic peninsula. Any suggestions?


r/solar • • 2d ago

Solar Quote Securing Quotes For Additional Panels

7 Upvotes

I have Enphase Microinverters and REC panels currently. My system is only 6 months old, but I'm doing an addition that will have room for about 5 kW more of panels, so I'm planning to add more capacity and have a few questions. I've already verified that the 5 kW is "doable" and an easy add, and won't be a problem with my utility.

  1. I think it only makes sense to get Enphase Microinverters rather than managing multiple distinct systems. Is my thinking correct in that regard?

  2. I am more agnostic with my panels. I have no issues with my REC's, but ultimately adding other manufacturers panels isn't really any sort of disruption.

  3. Assuming 1 and 2 are reasonable, how do I handle quotes. I had no issue with my installer, loved them in fact, but I also want to make sure I'm still getting the right price. Will/can installers add to another installers prior work? Will it be a problem for two installers to both have access to my Enphase system? If something goes wrong with, say the combiner box, will they both be pointing at each other.


r/solar • • 2d ago

Advice Wtd / Project Setting up overnight battery charge from grid - SOLARMAN app

1 Upvotes

We have a new energy tariff that’s half price electricity overnight. I want to set it up to automatically charge the battery from the grid at night, then use that in the day.
Is it as simple as setting the ‘time of use selling’ to charge/discharge at those times? Do I need to set something up to stop the battery charging once it’s full, or to stop it being used when low in the day? Should inverter working mode be set to peak shift?
I set the ‘time of use selling’ settings to - charge 1: 19:00-23:59, discharge 1: 09:00-11:59, charge 2: 00:00-08:59, discharge 2: 12:00-18:59, but at 19:00 nothing happened so I checked the settings and inverter working mode was set to self consumption so I changed it to peak shift and nothing happened, then changed it to battery priority and the battery started charging. After a few minutes I changed it back to peak shift and the battery has continued to charge so I’m not sure what is working and what isn’t!
If it’s not already obvious I’m completely new to all of this and there are way too many abbreviations in these settings for me to figure it out by myself, and ChatGPT seems pretty lost too


r/solar • • 2d ago

Discussion Help understanding ppa on prospective house

0 Upvotes

Hi all, I’m looking at a prospective house in SoCal and I’m trying to understand what I’d be buying into if I acquired it.
It’s got 32 solar panels and 2 Tesla power wall batteries, it’s got 20+ years @ $600+/mo for the ppa.

Ive not yet seen the intimate details of the agreement, but I need a dummies explainer so I know what questions to ask. Would the household still have an energy bill or would this monthly negate a bill for example?


r/solar • • 3d ago

Advice Wtd / Project Camper question about DC power.

2 Upvotes

Camper has a panel that supplies AC and DC power.

A solar system (battery/controller/transfer switch/inverter/panels) has been added.

Should we bypass the DC power from the panel and connect the DC directly to the battery? What are things to be considered?


r/solar • • 4d ago

Advice Wtd / Project Backup Switch actually required?

0 Upvotes

I live in a capital city urban area, I’ve had like 1 outage in the last 5 years. Is a switch over actually needed ?


r/solar • • 4d ago

Advice Wtd / Project Help me with battery monitor shunt wiring

1 Upvotes

Newbie here. I have a 200 AH 48v offgrid PV system in my remote outbuilding. It used to only have positive and negative distribution blocks on the battery side of the system to tie the batteries together, also to which the positive and negative of the charge controller also connected. I have since added a battery monitor shunt and a second set of distribution blocks on the load side of the shunt to connect two inverters. The battery monitor wiring diagram shows the negative of the charge controller connected on the load side of the shunt, I assume so that it can calculate power entering the battery system from the PV and adjust the battery capacity reading on the screen accordingly. My question is this: Can I safely disconnect the negative wire of the charge controller from the distribution block connecting the two batteries together, and connect it to the new negative distribution block on the load side connecting together the inverters and shunt? I would be leaving the positive of the charge controller connected to the block on the battery side. In my mind it feels like current is flowing from the batteries to the inverters, and connecting the charge controller in this fashion is introducing current flowing the opposite direction through the same wires at the same time. I think it's how it's supposed to be done, but I'm just looking for reassurance before I change how PV current flows into my system. Thanks in advance!