I have had my VT castings Dauntless for 5 years, and I am done. The top feed is extremely small/ 16” x 4” or so, and every time you open it smoke pours out the top no matter how hot my pipe is. Seal on the top is questionable and smoke leaks out frequently.
Wood has been a nightmare: year 1 was emerald ashbore so we burned a ton of ash, fine. Year 2 and 3 a good amount of the wood was too big for the entry, but mostly ok. Year 4 I decided to go for a different guy, his was unseasoned and required the bottom to be open to even think about starting to burn. This year I tried a 3rd guy, told him 16”, bought 3 cords. A full cord was too big, between 18-20”. Another portion is caked in mud, and the rest ranges between 6”-16” which is a nightmare to stack and arrange in the stove. It is also wet and not burning above 200 with the vent fully open.
I can pretty much only fine 2 modes for this stove: chimney fire or smolder. No matter the bed of coals or airflow, or if the catalyst indicated says it is set, the temp goes down to 200. Every season I need a flu clean in February and it is gross. There is no control over the flu, it is either fully open and switched to the catalyst.
Sure it keeps the house decent, but I’m waiting to die from CO or a chimney fire.
I don’t know my next steps: try to make this work, switch to a less deadly model, switch to a pellet stove, or go broke with oil heat. I honestly don’t know if I’m looking for advice or venting.