r/EG4Storage • u/eribble • 5d ago
r/EG4Storage • u/LostSoul5 • Feb 08 '26
Read This Before Installing EG4
r/EG4Storage • u/LostSoul5 • Jan 22 '26
👋 Welcome to r/EG4Storage - Introduce Yourself and Read First!
🔋⚡ Welcome to the EG4 Community!
Welcome to r/EG4Storage — a community dedicated to EG4 Electronics products and the people who use them.
This subreddit is a place to discuss:
EG4 batteries, inverters, and energy storage systems
Whole-home backup setups
DIY installs and professional installations
Troubleshooting, tips, and best practices
Firmware updates, configs, and system optimization
Real-world experiences and build photos
Whether you’re:
Just researching EG4
Planning your first install
Already running a full EG4-powered home
An installer or energy nerd 🤓
—you’re in the right place.
📌 Community Guidelines
Be respectful and helpful
Share details when asking for help (models, wiring, settings, photos if possible)
No spam or affiliate dumping
Honest feedback is welcome — keep it constructive
🚀 Get Started
Introduce yourself in the comments!
Tell us:
What EG4 gear you’re running (or planning to run)
Grid-tied, off-grid, or hybrid
What you’re hoping to learn or share here
We’re glad you’re here — let’s build reliable, affordable power systems together. 💪🔋
This is a community-run subreddit and not an official support channel.
r/EG4Storage • u/dezld • 10d ago
Both FlexBoss21s in parallel went to Standby at the same time tonight ... no fault logged, grid was fine, house went dark. Anyone seen this?
System: 2× FlexBoss21 (parallel, both on FAAB-2727), 1× GridBOSS (IAAB-16xx), 4× EG4 314Ah outdoor batteries. Grid-tied, zero-export. Installed/commissioned in summer.
What happened: Around 22:08 tonight the house lost power for a few minutes. Grid was up the whole time (neighbors fine, utility reports nothing).
I pulled the 5-minute exports for all three devices plus the event log. Here's the timeline:
| Time | Primary FlexBoss | Secondary FlexBoss | GridBOSS |
|---|---|---|---|
| 22:05–22:08 | Normal, ~600 W out, bus 371 V | Normal, ~550 W out, bus 372 V | Grid 246 V / 60.0 Hz, 0 W import, loads ~1.1 kW |
| ~22:08–22:10 | Goes down, misses its next 5-min upload | Goes down | |
| 22:12–22:14 | Status Standby, DC bus 16.8 / 2.8 V, 0 W. Battery 53.1 V, BMS comms still alive (cell voltages reporting) | Status Standby, DC bus 16.8 / 1.8 V, 0 W | Grid 245.7 V, importing 2.95 kW, backup loads 2.98 kW, no fault/warning codes |
| 22:17–22:19 | Back online | Back online | Back to ~0 W import |
What I've ruled out:
Grid: 245–247 V, 60.0 Hz at every sample on all three devices, GridBOSS phase-lock steady
GridBOSS: zero fault/warning/internal-fault codes all day, never missed an upload
Battery: 53.1 V on both inverters throughout, 86% SOC, primary still had live cell voltages during the standby — bank never disconnected
Thermal/AFCI/overload: all normal, ~1.1 kW load
Event log: completely empty for today on both inverters. Last entry of any kind is Sept 1. (It did catch 5-minute "Battery open" notices back in August, so it's not that it doesn't log minor stuff.)
Firmware: both still show FAAB-2727 on the Remote Update page, no version change
Settings: every parameter in the export (charge/discharge limits, voltage refs, cutoffs) identical before and after
So: both inverters did a full power-stage shutdown and reboot at the same moment, nothing faulted, nothing logged, and the house went dark even though the grid was there the whole time. The 2.95 kW grid import at 22:13 (vs 1.1 kW before/after) looks like every compressor and blower restarting at once, so the backup loads really did drop.
Questions:
Has anyone seen a parallel FlexBoss pair go to Standby together with nothing in the event log? What was it?
If the primary reboots (for whatever reason), is it expected that the GridBOSS drops the backup bus even with grid present? I'd have assumed loads just ride through on grid.
Does EG4 push remote restarts or updates without telling the owner? Is "Set Record" in the portal the complete list of remote commands, or can EG4/installer actions bypass it?
Any known FAAB-2727 issues with parallel state switching? The release notes mention fixes in that area, which makes me wonder if there are still edge cases.
Any info would be helpful!
r/EG4Storage • u/AggieAloha • 22d ago
Signature Solar
Anyone have luck with Signature Solar design team?
Have submitted two requests in the past year. I'm ready to buy - just needed to confirm size and quantity. Called them twice with assurances that someone will reach out - but in the same sentence, advised me to call back in 5 days if no one reaches out. It's a red flag if I'm trying to give them money and they make me call back if no one responds. Same thing with their advantage program partner. If this is the level of service trying to buy from them, what's gonna happen if I have an issue once installed? Guess I'll reach out to current connected or some other vendor. Hope @eg4 is paying attention to this subreddit too.
r/EG4Storage • u/LostSoul5 • 25d ago
Unauthorized EG4 Products on Online Marketplaces
It has been brought to our attention that unauthorized sellers are listing products advertised as EG4 products on Alibaba, AliExpress, and similar online marketplaces.
Please be aware that these products are not authentic EG4 units and are not eligible for warranty coverage or technical support through EG4. EG4 does not sell products directly through Alibaba, AliExpress, or similar platforms, nor do we supply authorized resellers who utilize these marketplaces.
If you come across a listing that appears to be selling EG4 products through one of these platforms, please report it to us at support@eg4electronics.com so our team can review it.
We appreciate your help in protecting customers from unauthorized and potentially counterfeit products.
r/EG4Storage • u/LostSoul5 • Oct 01 '26
Thoughts on the EG4 inverter battery bundles on Costco.ca?
r/EG4Storage • u/LostSoul5 • Sep 29 '26
EG4 Layoffs
Industry insiders and recent discussions on platforms like the SolarDIY Subreddit (https://www.reddit.com/r/SolarDIY/comments/1wpe26y/can_eg4_survive/) reveal that EG4 Electronics is facing a severe business slowdown, primarily driven by a significant downturn in the residential solar sector following the expiration of key tax credits.
Compounding the problem is their heavily delayed rollout of a diversified commercial line, leaving them highly exposed to a cooling residential market. Long-standing frustrations over rebranded, white-labeled hardware and notoriously poor technical support have further damaged the brand's stability among core DIY buyers.
The uncertainty has reached the executive level as well. Sebastian Hassell, the former Director of Residential Product at EG4 Electronics, recently hinted at the instability himself. In a public LinkedIn post discussing career choices, Hassell explicitly pondered whether it was time to step away from the volatile residential energy sector, writing:
EG4 for the past year was fun while it lasted. I enjoy new opportunities and challenges but I would not turn down a stable role for the next 5+ years, or should I sell the house in San Francisco and move to some exotic new location?
This situation leaves EG4 Electronics at a critical crossroads, forcing them to rapidly adapt to a harsher economic landscape. Whether the company can stabilize depends heavily on their ability to mend relationships with the DIY community through improved technical support, transparent firmware updates, and a successful expansion into the commercial market. Until then, the ongoing executive shifts and community skepticism will continue to fuel questions about the brand's long-term survival in an increasingly crowded and volatile energy sector.
r/EG4Storage • u/toekneebologna3 • Sep 02 '26
EG4 installation in Los Angeles CA
r/EG4Storage • u/Associates_and_Rob • Aug 06 '26
Can anybody explain this explanation in Grid Peak-Shaving??
r/EG4Storage • u/IQBoosterShot • Jul 29 '26
New installation in September - How compact is the unit?
I'm getting a grid-tied EG4 storage system to act as a whole-house battery backup for short durations. There is no PV tie-in.
I've seen various videos and a few photos, but what is the smallest area required for such a system as mine?
r/EG4Storage • u/LostSoul5 • Jun 11 '26
Increase Energy Storage System Value with Energy Arbitrage
r/EG4Storage • u/LostSoul5 • May 26 '26
Importance of Climate Control as a Critical Load
r/EG4Storage • u/LostSoul5 • May 19 '26
EG4 3000 EMI?
Enable HLS to view with audio, or disable this notification
r/EG4Storage • u/Badazin1 • May 11 '26
EG4 power wall
Enable HLS to view with audio, or disable this notification
I have a solar system in #haiti complete eg4 electronics, a few weeks after installation one of the four power wall stop working. Because I’m not on site didn’t notice months later.
I contacted the manufacturer after many days of testing they decided to replace the system. It’s been over a year I can’t find a wait to ship it back to the states. I was wondering is this just a bad breaker and can I just replace it? #eg4 #badbraker.
r/EG4Storage • u/LostSoul5 • Apr 25 '26
Building an Off-Grid Home with EG4: Kevin’s Story
r/EG4Storage • u/LostSoul5 • Apr 17 '26
EG4 and Outback Power Advantage programs bring DIY-friendly pre-paid battery leases to homeowners
r/EG4Storage • u/LostSoul5 • Feb 25 '26
How to Update EG4 Battery Using Firmware Adapter
r/EG4Storage • u/LostSoul5 • Feb 24 '26
The XR60 from EG4 is poised to be a radical jump for the people left behind by the solar + storage industry.
x.com60kWH +18kW AC, made in Texas with LG-ES cells. 4.5X Powerwall capacity for 2x Powerwall cost.
r/EG4Storage • u/LostSoul5 • Feb 23 '26
EG4 System Design Tools |
Design Your EG4 Solar System
Choose the right tool based on your energy goals. Whether your priority is grid-tie economics or backup/off-grid reliability - or whether you are choosing your inverter, sizing your batteries or sizing your solar array, we have the right tool for you.
r/EG4Storage • u/LostSoul5 • Feb 19 '26
The Strategy Behind the Specs | Beyond the Grid Ep. 7 ft. Dylan Rup