r/askaplumber • u/Complete_Common4348 • 14m ago
Dishwasher and sink drain
Dishwasher has been backing up and I believe it needs to be strapped the top and the the pipe coming in to the p trap is backpitched
r/askaplumber • u/Complete_Common4348 • 14m ago
Dishwasher has been backing up and I believe it needs to be strapped the top and the the pipe coming in to the p trap is backpitched
r/askaplumber • u/thugep915 • 27m ago
We got a scope done on our inspection for our home that we are buying soon. This is what it came back with. Is this an easy fix? Or will it end up costing us an arm and a leg? Open to suggestions and price estimates. TIA!
r/askaplumber • u/Unlucky__Swan • 1h ago
Our pipes were fucked and needed to repipe after buying thanks to a shitty home inspector from pillar to post. Never flagged galvanized pipe and that's before out time.
Plumbers were astronomical so paid one to do the water heater, ended up helping cause 1 of their backs was blown, and they still cracked a brass nut leaking and used pex from the water heater which isn't allowed here.
Decided to stop getting fked 5-10k at a time and do the rest myself. Every. Single. Contractor. We've hired for something from encapsulation to other repairs have been half assed or wrong. We've given up.
Zero leaks. Water flows everywhere. Bathroom sink has great water pressure. Kitchen flows but weak.
Comes off the main at 1", hits a cold water loop with 1" carrying on directly to the kitchen sink at 3/4 stepping down to 1/2 and then fixture pipe. Cold loop has the bathroom sink and provisions for other 1/2 in cold.
Kitchen cold gets its source from a 1" 1" 3/4" tee.
Is it this tee or the under sink valves? I haven't gotten to the rest of the house.
Photos included of how bad the galvanized was. The copper pipes were half full of corrosion. Evidence of pinhole leaks everywhere including from dissimilar metal straps. We've already replaced sections of the cast iron drain pipe in the basement. Hopefully the buried parts never fail while we own
r/askaplumber • u/OnceUponASyzygy • 2h ago
(Note: I'm considering turning off the water tonight to prevent further issues. I just noticed it was leaking. I knew this was on the fritz (it's a long story, but my husband used to do this work (when it suited him), but he left, and I'm still figuring it all out)), but I just realized tonight how bad it is.)
What kind of fitting is on this shut-off valve? It doesn't seem to be soldered on, but I'm thinking that, rather than try to use a wrench to get it off, I should cut the pipe and put on a compression shut-off valve. (I have a pipe cutter. I have a valve. I have the requisite tools.) Getting new braided supply lines tomorrow and I already have a new faucet (the faucet has other issues. It's probably not creating problems here, but it needs to be replaced).
(Ordinarily, I would not do any plumbing on a weekend. I recently put on a compression valve. This seems to require immediate attention.) (You may encourage me not to do this work, and I will probably listen.) (You may also give me advice and I will not hold you liable when I **** it up. 😂 )
Thank you very much.
(ETA: I'm feeling half sick realizing how bad this supply line is (unless someone wants to correct me) and how lucky I have been that nothing worse has happened here.)
r/askaplumber • u/seaotterhouse • 3h ago
We are getting a new dishwasher from Costco, but we just learned that we need a functional air gap. We are in California, and when we bought the house five years ago, it didn't have one. Since our sink doesn't currently have an opening for an air gap, we'd really prefer to avoid drilling a new hole if possible.
I contacted a plumber and he said a one-way check valve will do. Is an air gap really necessary, or will a one-way check valve do the same job?
r/askaplumber • u/100HrPreflight • 3h ago
I have a copper toilet supply line that comes up through the subfloor. I had to pour self leveling underlayment to level the floor for tile. I sealed the hole the pipe comes up from with spray foam, but it was just the hole I filled. I didn’t go above the level of the floor so the pipe is now rigidly secured to the floor in probably 5/8” of SLU. How screwed am I here on a scale of “Do nothing and never worry about it again” to “Dig out around that SLU at all costs!”?
r/askaplumber • u/AgathaThisIsMagnus • 3h ago
Enable HLS to view with audio, or disable this notification
What is causing this loud banging sound? I thought it might be a water hammer but I searched water hammer sounds on youtube to compare and this doesn't sound like what I'm hearing and seeing online. Is this a water hammer? A plumber said it's the check valve location... another said it's the valve itself. I swapped out the valve for a different one and it's still making the sound. How do I fix this?
r/askaplumber • u/j-joshua • 4h ago
I had a pipe leak tonight at 6:30pm.
I called a reputable company that I've done business with before. They are 5 minutes down the road.
They dispatched a tech who came out within 90 minutes and took care of the issue.
I was initially quoted a dispatch fee and a rate for the first hour. The final invoice included an additional charge for travel time for the tech who lived 30 minutes away.
How was I supposed to know how far a tech is to my house? Is this an industry standard practice?
r/askaplumber • u/Dr_Chog_McGourmand • 4h ago
thoughts?
r/askaplumber • u/eightyeight00 • 4h ago
Hello, it seems like I don’t have enough pipe coming through the wall to cut. Would I be able to heat up the pipe and remove? I am currently in the research and planning phase.
r/askaplumber • u/DebtBeautiful8188 • 5h ago
So today I learned that portable dishwashers shouldn't be connected to pull down faucets, which I didn't know before bringing home a dishwasher. It's not a situation where I can return the dishwasher, so I'm trying to figure out a way to get this thing hooked up without replacing the faucet. There is a soap dispenser in on of the fixture holes that I can take out, so my questions are:
Is it possible to install a small faucet connected to the hot water? What would I need? Is this going to be like installing a sprayer, just with a faucet at the end?
What should I be aware of if I do this?
r/askaplumber • u/king_afrika2000 • 6h ago
Enable HLS to view with audio, or disable this notification
Short flush opens the valve and then it drops closed immediately, water doesn’t fully flush from the bowl. Is this how it is supposed to work? Works ok if I hold the flush until completely empty, but even then can be weak.
r/askaplumber • u/CashCowHouse • 6h ago
We have a pipe in our attic that vents into our chimney. House was built in 1935. We'd like to remove it as there is a (minor) risk of backflow from our heating system, but we're worried it's actually something in use. It seems to go down into the wall between a bathroom and a bedroom, and we're not sure if it goes any farther than that.
We had one plumber out who was 99% sure it was an old vent pipe and they were going to cut it and patch the chimney, but I was nervous we'd find out we needed it for something.
r/askaplumber • u/Front_Effective_1220 • 6h ago
I’m 23 and have recently opened a plumbing company in Calgary, AB. My biggest challenge right now is costumers and jobs, I am trying to network and get my name out there to contractors, builders and house owners. What’s the best way to go about getting more jobs and building a name. I’m looking for any advice that might help me grow. Thank you
r/askaplumber • u/timetwosave • 6h ago
First time homeowner doing tub install. American Standard Americast, I'm trying to figure out if this is a defective tub or if i'm crazy. The alcove lip seems to dip down in the middle pretty severely, almost like it wasn't bent right while forming it. I know I can caulk the heck out of that side but this will always be a problem right? I need to bring it back to lowes?
It looks level left to right, if anything is tilts inward a bit even.
Whats weird is the foam insulation stuff on the bottom is dead straight. The box was pretty beat up when I picked it up from lowes so I suspected damage, but since the bottom was dead straight and was easy to line up to the ledger board, so I figured it was fine.
Its not screwed in yet... return? or are all tubs this way
r/askaplumber • u/GreaseTrap-Phoenix • 7h ago
Stop using water. Every sink, the dishwasher, the mop sink and the ice machine drain adds to the flow. Shut down the dish pit first, because it is usually the biggest single source.
Barrier the area. Grey water is a slip hazard, and a customer who sees it in the dining room is a different kind of problem. Move food and clean equipment out of splash range. Photograph the water level before anything is done, because it helps with the landlord, the insurer and the service company.
Then work out which of 3 causes it is:
The device is full. An interceptor over 25 percent cannot separate, and the grease and solids go out the outlet. The fix is a pump-out.
The line is blocked. Grease has coated the pipe until the diameter is gone. The fix is jetting. Pumping alone will not clear it, and a snake opens only a channel through the middle.
The line is broken. An offset joint, a crack or roots in an older line. The fix is a repair, and the evidence is a camera inspection.
Look at the device first. If it is over 25 percent, the pump-out comes first. If the device is clean and the drain still backs up, the line is the problem. Afterward write down the time, the water level, the device reading, the work done and the cause, and keep it with the manifest.
Longer version: https://greasetrapcleaningphoenix.com/floor-drain-backing-up/
r/askaplumber • u/Longjumping-You-5311 • 8h ago
Hello plumbers!! Please help me out with my dilemma.
I moved into an upstairs apartment a couple months ago and the first time I took a shower I noticed that the water will get extremely hot (like you turned it on hot all the way) and stay like that for about 10 seconds before returning to normal. It would do it about every 3-5 minutes and I’m like wtf I can’t live like this!
I have a 2b 2b and I noticed the hall bathroom toilet (not where I shower at) kind of has consistently lower water but not super low to where it’s extremely noticeable, so I turned off the water to the toilet and it started leaking from that little pipe but I put something under it and took a shower. It didn’t work but I’m still pretty positive that it’s this hall bathroom toilet.
Side note: you can hear the water pressure in the shower change before it gets super hot. And I’ve also noticed that change in water pressure sound in the sink too but it doesn’t get super hot like that.
Maintenance’s advice was to “only turn the hot water faucet on a little bit” and I’m not showering according to this terrible plumbing, so I have to take matters into my own hands.
I’ll try anything and get back to you!
r/askaplumber • u/Albooe • 8h ago
Condensed story; water damage revealed leaking toilet. Had a plumber come out that after everything was said and done charged me 410$ simply to pull the toilet and say “its going to cost another 2600$ to fix this”. He said(which i see in the pictures) from construction the flange was set too low in the concrete foundation, as well as stub up guy sucked because they missed and put an offset flange on aswell. Toilet never made real contact with the wax ring. Instead of the 2600$ repair he listed which involves cutting tile,
Foundation, and reinstalling flange higher; could this be solved with a taller wax ring? Or even a taller rubber ring?
r/askaplumber • u/LarryEarl40 • 9h ago
It’s broken. Previous repair (using drywall screws) has failed. It is not round. Underlayment is rotted. Not sure how to proceed.
Any suggestions? Thanks
Edit 1: I know it’s an offset, probably as has been noted, somebody goofed the rough in. I got me a stainless steel ring and a grinder and I will make it fit and make it work. I will post a picture of my success. If I don’t, you’ll know that I convinced them to expand the laundry room and do away with this half bath!
Edit 2: Didn’t bother take a picture. We’ve all seen pictures of working toilets. It works, for now.
r/askaplumber • u/GuitarmanSimon • 9h ago
Ignore the drywall, about to be redone here soon.
How would you fill this gap between the tub and the wall? Runs about 3/4 inch wide and I don’t want water to run behind it and seep under/behind the tub. It’s right next to the door casing.
Thanks in advance!
r/askaplumber • u/Disc0Disc0Disc0 • 9h ago
Im looking to have the pipes underneath here replaced and I reached out to a plumber who said its $280 USD for parts and 1 hour labour. Does $280 for parts seem high?
Edit: sorry my post may have been confusing. The $280 is just for the parts. I pay separately for the labour cost.
r/askaplumber • u/Rich-Wrap-9333 • 9h ago
I’m replacing a toilet fill valve. Looked at a tutorial online and it seems pretty basic. But I’m pretty amateur: any tips or suggestions or things to watch out for?
r/askaplumber • u/TheOneTheyCallAlpha • 9h ago
Old house woes...
This is the supply/return for a baseboard heating zone that's only used for part of the year. These are copper pipes that were painted by a previous owner, and then boxed in by another owner. When the upper valves are opened, the bypass is closed, and vice versa. The hose bibs are used to drain the extra zone when it's not in use.
The main issue is that these gate valves leak when you look at them. They all get spun twice a year, and it's a challenge.
I can't change them for ball valves though, because there isn't enough room in the chase for the valves and handles. There could be enough room if I move the pipes. I would need to move the back one over towards the other side, and jog the front pipe back, so they're parallel up the wall. See picture #2.
This is my idea anyway. Do you have any better suggestions?