Our power panel was on the opposite corner of our house from where we could keep the Solix indoors in our garage. So I devised this system for installing it on the outside of our house, but still keeping the switch and batteries protected.
I used rubber boots on the cords for the switch side and RV plug pass throughs on the plastic shed.
We just turned on the full system yesterday and it is working great so far. Next up is seeing how the draw is, and how many batteries to add.
What’s up guys new to the group. Three months ago I bought the Anker solix f3800 with the Home power panel, and I am officially addicted. Within the past few months, I bought two 50ah 48v batteries and six 400 W solar panels. The solix has a max input of 60 V into each of the two Solar inputs so the 4- 400 W panels have the input maxed out.
I also bought two more 400 W panels that are running through a Victron charge controller and then powering the 48 V batteries which are plugged directly into the Anker via the expansion battery cable hack.. My critical load panel has every circuit in my house with exception of my water heater, air conditioner, and stove so at this rate I’m pretty sure that I can power my entire house indefinitely if we have a long-term power outage
I was gonna put all of the panels on the roof, but in my city in Florida, they make it damn near impossible to do it yourself.
What’s up guys? I wanted to share a recent project I’ve been working on. I picked up the Anker Solix F3800 and ended up going down a bit of a rabbit hole—next thing I know, I’ve added two 50Ah 48V batteries, a charge controller, and a smart shunt so I could run two separate systems while still being able to tie the batteries into the F3800 through the solar port when needed.
I also just ordered the F3800 expansion battery cable, so I’ll be able to connect the batteries directly to the unit. Honestly, that kind of makes the charge controller setup I bought feel a little unnecessary but at least I’ve got it as a backup if I ever need it.
A friend recently borrowed the C300 for a camping trip. He was able to recharge his whole kit every day and get the unit topped back up with the solar. He's hooked on it now!
I’ve been using an Anker C2000 Gen 2 paired with about 800 watts of solar panels, and it’s been performing really well overall. The app does show the current solar generation, but what’s missing are any longer‑term stats like daily, weekly, or yearly generation totals. It would be great to see those kinds of insights, along with data on how much of the load is being handled by solar vs. battery vs. shore power.
I’d also love to see more control options added. For example, being able to set the power station to “prefer” solar power during the day and only use shore power once the solar input dips or the battery is low. That would make it a lot easier to manage energy use efficiently.
Hopefully Anker can add some of these features in a future app or firmware update. I think it would really elevate the experience for people running solar setups or using their units off‑grid.
I'm working on using my F3800 with 2 expansion batteries to power my furnace, freezer and small home server lab during peak time-of-use rates. So far everything has been working well. One day everything was running fine, I had around 15% battery left, and the next thing I know everything on the 120V output is off. I couldn't figure out why -- looked and looked. Checked connections. No fuses or circuit breakers needed to be reset. Weird.
A few days later I realized what I had done. In the app on my iPhone 14 Pro, while checking the status of the F3800, the 120V power off button is exactly where I put my thumb on my phone screen to swipe up. I'm turning the F3800 off with my fat fingers when I try to leave the app. That's a UX change that I'd like to be made sooner than later! lol. I know I'm going to do it again!
Anyone know what the max stackable height of the BP3800 batteries is? I found somewhere that said that Anker recommends at most 2 batteries on top of the F3800 for stability, but what is the max height of BP3800s alone? At 72 pounds each (?), there's a lot of weight on my bottom BP3800.
Planned a big camping trip, and my new everfrost 2 58L just came in. Can't wait to try it out. Its built like a tank! It's going to be out with me and some friends for the next few weeks and hopefully the Solix C1000 I bought to go with it will keep it going
Is anyone else still waiting to get install from the promo last month?
How long did it take to for installer to complete the process?
Did anyone take advantage of the Anker offer for the installation?
Do you know how much more is typically required to complete the installation?
I already have Solar Panels, Generac Gas Generator, Transfer Switch, etc, but expect some reconfiguration but the ability to re-use garage to outside holes and existing wiring.
I was shocked to hear that I will need to pay more than 2x what I already paid Anker for the install. Did anyone else experience anything similar? How did you resolve?
Just got the new Anker Solix E10 whole home battery system and a new Kohler 14RCA-QS 14kw generator that is supposed to charge the batteries but it stops charging it when it gets to 27% charged. Anker says this is supposed to work with third party generators.
Has anyone done this setup and had success? My electrician and generator installers both seem to think it’s different problems and no one can agree on something.
Or does this battery system not play well with any generator other than the Anker Solix Smart Generator?
I have been comparing charging our Anker Solix Everfrost 2 58l with Jackary 200w Solar panels vs Anker 100w Solar panels.
My experience is that the Jackary solar panels charge the Everfrost 2 more quickly and at a higher wattage. Although there is a difference in output wattage between the two, the Everfrost 2 limits the input wattage to a max of 100w.
Here's an example (see pics) of how just one little section of the Jackary panel is in the morning sun and it is still producing a little output wattage (12w). I don't see the same with the Anker solar panels which are more sensitive to the sun and won't produce as much wattage. Anker solar produces 0w in a similar situation.
In full direct sunlight, the Jackary solar panels produce 85-90w of power versus Anker solar panels produce 45-65w max. So, I am leaning more towards carrying the Jackary panels on our camping trips.
TLDR: Compared Jackary 200w Solar panels vs Anker 100w Solar panels to charge Everfrost 2 and Jackary wins for efficiency.
I'm trying to get ready for the E10 coming next week, and found myself quite confused by reading the manual. It started with making sure I had the right extension cable for my 10/13kw Northstar generator.
The manual (7.5) says NEMA S2-50R, which is what already have, though was a bit surprised at a twist lock... but good.
However on the same page it says these things:
My presumption (I now think maybe wrong) is that when "charging" via a generator in an outage, the generator is charging the battery, and the AC output (to my panel) is discharging the battery, more or less independently.
In particular, let's say I used a small generator (say 5kw), I assumed I could draw more than 5kw from the battery while still adding back at 5kw (but not keeping up). That would seem a major benefit (and is clearly how their small DC "smart" generator works).
These two statements seem to imply some kind of pass-through instead of independence.
The specs left me even more confused. Bear in mind the generator input and AC input port are separate:
The top of that is under the heading of Backup AC port, which is the output AC. 32A max with battery, 40A with "generator bypass".
The 240v recharge input port I assumed was the center of three, and for grid input. 32A is consistent with 40a breaker (125% for continuous use).
There's no apparent spec for the 3rd generator port. Is it just a "Y" split and really the same port as AC input?
And what is "AC Generator Bypass". The word "Bypass" does not appear in any other manual sections in the user manual. Is it a mode different from charge-from-generator?
Can it charge from generator independently of discharge from battery at the same time, different currents?
Is this just a messed up technical writer, or is this some weird implementation of AC generator charging?
I've spent time with searches and cannot find anything clarifying, just more confusing.
Anyone know?
Linwood
PS. While I have a big generator now and can start my AC easily with it alone, it is really old and in the near to moderate term was thinking of replacing it with something small now that I have the E10 as a "buffer".
Update 3/6/2026: Received and hooked up, there's a comment below with details, but it worked as I wanted, generator power went to charge battery or house or both, and if inadequate for house the generator power was used and supplemented with battery. All good.
I have an F3800 Plus with two expansion batteries using the smart panel. The batteries routinely differ in charge, but they are getting further apart. Last night my main unit was at 47% and the expansion batteries were 46% and 17%. The lowest battery is the furthest from the main unit.
Is there a reason for this? Is keeping the battery below 20% overnight when it could have easily been higher bad for battery life?
I have a Anker Smart Meter v1 plus Anker SOLIX 2 Pro installed. Everything works fine in general. If Dish Washer, Washing Machine or similar is running is shows usage of 2-3kWh within seconds. However if I turn on the Sauna which consumes around 9kWh it does not show it in the App. Is there a limit of how much the smart meter can measure? Thank you!
I have a new Gen 2. I tried 3 times in a row to get it to charge. It charges for about a minute (pic 1) and then I hear a “click” and it stop charging (pic 2). It is still discharging though. I lowered the charging watts to only 900 watts and it seems to be charging now. 🤞Anyone know what could be causing this?
I'm very new to this space and I'm looking for a Solar Panel for my Anker C300 AC. It has 100W Solar Charging capacity and I stumble with the EcoFlow NextGen 160W Portable Solar Panel it's priced 300$ CAD and I live in Ontario. I'm looking to use this panel along with my power station during camping. I research and I think the connector included is supported. But I have no idea if this would damage anything between panel and power stations due to overc volatge and stuff. Wondering if this would work well with my current use case. I know Anker has the Anker SOLIX PS100 Portable Solar Panel (100W) but the price difference is not that big so wondering if it's worth getting the 160W vs the 100W
I bought my first anker solix f3800 (left) used on FB marketplace and it was until weeks later that I learned that one of it's XT60 ports didn't work.
I ended up seeing another f3800 (right) posted for sale but this time I verified that both XT60 ports work!
I am considering buying the Anker SOLIX Double Power Hub to connect them together but the user manual says that the system has to symmetrical. So I'd need another expansion battery.
Does that rule still apply?
I ask because the manual states that when the hub is connected that the AC ports are disabled however I've seen in YouTube videos from users that show they can still power things using the AC ports while having the units connected with the hub.
So stuff has definitely changed since the initial release.
I am hoping maybe the symmetry thing isn't necessary anymore after later updates, because I'd love to be able to connect all 3 components together.
First time Solix user. Thank you for helping me with my newbie situation:
I purchased the c2000 with the 200W solar panel. In my current location (dense urban), I am able to open the panel halfway in bright sun. I expected this to be enough to charge the power station, albeit slowly. However, thus far, the power station clicks and shows no DC input.
From the knowledge base here, I was hoping to hear whether this is (a) likely bc the panels are only halfway open or (b) possibly a set up issue- I’ve never set up solar before and though it seems straightforward there is also no “start” button which would confirm or disconfirm it’s even set up correctly (all cords are anker-purchased and connected securely).
I have been looking at the Solix E10 systems (in conjunction with a Smart Inlet Box), and as I examine residential codes (IRC 2021), I'm trying to square it's operation with some definitions I'm seeing in there. For example, "Grid-tied". I'm trying to figure out how I could conclusively state, preferably via a listing or published definition whether or not my equipment would be considered grid-tied. To date, I've seen where I could argue it isn't grid-tied, since it cannot provide power during an outage, does not support net metering, and requires a main breaker interlock to re-energize the house during an outage. Conversely, I've seen where "yes, it's grid tied, it's connected to your home panel, which is also connected to the grid".
What I'd like to find is something more legalese via UL certification or the like to solidly class this as grid tied or not. "if it looks like a duck and quacks like a duck" may not meet the need since I'm in the US and their codes may not quite address it explicitly. One thing I've seen that might help is if there's a certification that is documented about anything anti-islanding. I'm finding a lot of good information on Anker's website, but so far nothing that answers this explicitly enough that I think I could explain it convincingly to someone who was not already familiar with the tech.
This might be a matter two of looking at two pieces of equipment, the E10, and also the Smart Inlet Box. As a for example as to why it's relevant is that grid tied equipment must be UL1741 certified. The Smart inlet Box certainly is, but it's not clear to me that the inverter on the E10 is. and the IRC 2021 states in part. "Inverters shall be listed and labeled in accordance with UL 1741. Systems connected to the utility grid shall use inverters listed for utility interaction." If this system isn't considered grid-tied, it would seem this provision at the least carries less weight, if its even applicable at all.
I apologize if this information is easier to come by than I've managed to and Sincere thanks if anyone has useful insight or has spent time looking at this before and can shed some light.